Factory Test & Alignment Specification For MS08EP-LA Series (V1.0)
0- DeviceID test submenu
Item
DeviceID
test
Appendix
"Instructions of Updating DID,UID and MAC"
1,use the Uart command to sent DID and MAC using the command :
DID write: B2 DATA 0 TO DATA N(ASCII )
UID write:B8 DATA 0 TO DATA N(ASCII )
MAC write:B3 MAC address 6 (Binary)
The process is as the picture below:
Portal give the UID and DID to the factory local service ,and the service connect to the factory LAN.
When product line produce the IPTV , there will be a work station (PC normally) down load the DID , UID
and also MAC from the local service ,then using UART command sent them to the module.
2,How to test the function:
When there is a module need to test the Device function connect the set to the LAN use the device ID test the
module will sent the device ID information and user ID information to the local service and compare with the
data-base .so that the data is verified .