Lennox Signature XC17 Installation Instructions Manual page 23

Table of Contents

Advertisement

Board ID
E12
E16
E18
E21 and E22
E31 and E32
E24 and E25
E26
E27
E28
E30
E33
W1
* Factory default setting
Downloaded from
ManualsNet.com
Table 3. Main Control Jumpers and Terminals
Label
Description
PSC Fan
240 VAC output connection for outdoor fan.
PSC Fan
240 VAC input connection for outdoor fan.
W
24VAC output for defrost auxiliary heat output.
L
Thermostat service light connection.
Y2
24VAC thermostat input/output for second stage operation of the unit.
Y1
24VAC thermostat input for first stage operation of the unit.
O
24VAC thermostat input for reversing valve operation
DS
Humiditrol Input
C
24VAC system common
R
24VAC system power input
LO−PS
S4 connection for low−pressure switch (2.4 milliamps @ 18VAC)
Y1 OUT
24VAC common output, switched for enabling compressor contactor.
HS−PS
S87 connection for high−pressure switch.
First Stage and second stage basic and precision dehumidification ECM fan motor 24VDC out-
FAN 1
put connection 1.
Second stage basic and precision dehumidification ECM fan motor 24VDC output connection
FAN 2
2.
FAN C
ECM common connection for ECM fan.
Six position square pin header E30 provides connections for the temperature sensors.
DIS 5
Discharge line temperature sensor supply.
DIS (YELLOW)
DIS 6
Discharge line temperature sensor return.
Pins 5 and 6
Range is −35ºF to 310ºF. Sensor is clipped on a 1/2" copper tube.
AMB 3
Outdoor ambient temperature sensor supply.
AMB (BLACK)
AMB 4
Outdoor ambient temperature return.
Pins 3 and 4
Range is −40ºF to +140ºF
COIL 1
Outdoor coil temperature sensor supply.
COIL (BROWN)
COIL 2
Outdoor coil temperature sensor return
Pins 5 and 6
This model does not utilize a coil sensor. The cable harness assembly for the sensors
incorporates a built−in 10K resistor between pins 5 and 6.
This jumper allows service personnel to defeat the timed off control, and field programming of
Field Test
unit capacity feature. Placing a jumper across both pins on E33 will terminate the anti−short
delay. It will also clear lockout alarms
Short DS To R
Cut for Humiditrol
search engine
Enhanced Dehumidification Accessory (EDA) applications.
Page 23
XC17 SERIES

Advertisement

Table of Contents
loading

Table of Contents