Conversion Kit# 381-969 From Ng To Lp - FPI Hampton H15U-NG Owners & Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Conversion Kit# 384-969 from NG to LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION!!
LP Conversion Kit contains:
Qty.
Part #
Description
1
904-434 Burner Orifice #55
1
918-590 Label "Converted to
Propane"
1
908-528 Red "LPG" label
1
904-529 5/3" Allen Key
1
910-037 LP Injector (Pilot Orifice)
1
920-467 Instruction Sheet
Installation of LPG
Conversion Kit:
1)
Shut off the gas supply.
2)
Lift off Cast Top, remove Cast Front and
Glass Door (refer to the glass replacement
section in the manual) and carefully remove
logs and lava rock.
3)
Remove burner by removing the 2 screws
on each side and then slide the burner to
the left and lift out.
Screws
Note: Use a magnetic type screwdriver
if possible.
Pilot assembly
is now
accessible
for steps the
following
steps.
920-467
Hampton® H15U-NG/LP Direct Vent Freestanding Gas Stove
Conversion Kit #384-969
from NG to LPG for H15U
IF IN DOUBT DO NOT DO THIS CONVERSION !!
4)
Turn control knob to the "OFF" position.
5)
Remove the Hi/Low extension knob by
pulling it towards you. This will expose the
black protection cap. Remove the black
protection cap by hand from the high-low
knob (Fig.1).
Fig. 1
6)
Insert a 5/32" or 4mm
Allen wrench into the
hexagonal key-way
of the screw (Fig.
2), rotate it counter-
clockwise until it is
free and extract it.
7)
Check that the screw is clean and if
necessary remove dirt.
8)
Flip the screw (Fig. 3).
9)
Using the Allen wrench as shown in Fig.4,
rotate the screw clockwise until snug, do
not overtighten.
Fig.4
Fig.2
Fig.3
1
installation
WARNING!
Do not overtighten the screw.
Recommended to
grip the wrench by the short side.
10) Verify that if the conversion is from NG
to LPG, the screw must be reassembled
with the red o-ring visible (Fig. 5).
LPG Configuration
Red o-ring visible
Fig.5
11) Reassemble the black protection cap
(Fig. 6).
Fig. 6
WARNING!
Also check that the pilot and main
burner injectors are appropriate for
the gas type.
16) Reverse steps 3) to 2).
17) Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
18) Replace yellow "Natural Gas" label with
red "LPG" label.
H15U
35
02/18/22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hampton h15u-lp

Table of Contents