BEA ULTIMO Manual page 10

Activation and safety sensor for automatic, sliding doors
Table of Contents

Advertisement

3
ACTIVE INFRARED SAFETY FIELD
NUMBER OF CURTAINS / POSITION OF CURTAINS
(IR:CURTAINS, MENU 1)
Choose the number of and position of the AIR curtains based on your application.
NOTE: The sensor is defaulted to Non-Threshold setting (3). If threshold is desired, you may
choose Threshold setting 1, 2, 4, or 5; be sure that the curtain placement matches the LCD
screen.
If necessary, use visible spots and red adjustment knob to position properly (see page 11).
* When IR:Curtains is set to 0, the AIR will not trigger the output for a period of 5 minutes.
After 5 minutes expires, IR:Curtains will revert back to the previously chosen setting.
GENERAL SETTINGS
THRESHOLD SETTINGS
NON-THRESHOLD SETTINGS
Page 10 of 20
UNDERSTANDING THE LCD "CURTAINS" GRAPHICS
the number of squares on a line indicates the curtain number (i.e. C1, C2, or C3)
the rectangles on each side of the setting number represent sliding door panels
a dotted line indicates that the given curtain is active at full open, and inactive during door
closing cycle (settings 2 and 5)
a solid line indicates that the given curtain is active at full open and partially active during
door closing cycle (settings 1 and 4)
a solid line indicates that the given curtain is always active (settings 3, 6, and 7)
DEFAULT
75.0034.03 ULTIMO 20220120