2. Location selection

2.1
Unit location selection can refer to
installation manual.
2.2
DO NOT install the unit in the
following locations:
Where oil drilling or fracking is taking place.
Coastal areas with high salt content in the air.
Areas with caustic gases in the air, such as near hot
springs.
Areas with power fluctuations, such as factories.
Enclosed spaces, such as cabinets.
Areas with strong electromagnetic waves.
Areas that store flammable materials or gas.
Rooms with high humidity, such as bathrooms or
laundry rooms.
If possible, DO NOT install the unit where it is ex-
posed to direct sunlight.
2.3
The minimum distance between the
outdoor unit and walls described in
the installation guide does not apply
to airtight rooms. Be sure to keep the
unit unobstructed in at least two of
the three directions (M, N, P)
M
N
2.4
Rows of series installation
The relations between H, A and L are as follows.
L ≤ 1/2H
L ≤ H
1/2H < L ≤ H
L > H
Page 114
P
L
A
25 cm / 9.8" or
more
30 cm / 11.8" or
more
Can not be installed
H
DO NOT install the rows of series like following figure.
2.5
If the location is exposed to strong
winds (for example: near a seaside),
the unit must be placed against the
wall to shelter it from the wind. If
necessary, use an awning.
DO NOT
L
Strong wind