Unit Installation

Unit installation
I
C
NDOOR
OIL

Coil Location

The indoor coil is designed for installation in
conjunction with a duct gas central heater
within a ceiling/roof space or other
compartment, where there is no influence
from outdoor conditions.
While selecting the location, the following
conditions must be assured:
a) The location should assure free flow of the
return air into the central heater without
interference.
b) The unit should not be installed close to
rooms where noise should be avoided
(bedrooms, children rooms, etc).
c) Consider air distribution from the unit to
the rooms and select a suitable location
for even air flow.
d) Avoid obstacles which may restrict the
return air intake or the discharge supply air
flow.
e) If installing the indoor coil on a platform
ensure that the structure is capable of
supporting the indoor unit and platform.
NOTE: The indoor unit should not be installed
outside.
Installation Instructions
C
C
OOLING
OMPONENT
1.
Ducted Gas Heater
2.
Ducted Gas Heater Platform
3.
Transition duct – air on
4.
Suspended hanging option –
indoor fan coil
5.

Indoor Coil

6.
Platform Option – Indoor fan coil
7.
Transition duct – air off
8.
Discharge Air Grilles