Certification
6.2 EMC and Environmental Type Tests
IEEE 1613 EMC Immunity Type Tests
Environmental Type Tests
30
Description
ESD
Enclosure Contact
Radiated RFI
Fast Transient
Earth ground ports
Oscillatory
Test
IEC 60068-2-1
Cold Temperature
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-6
IEC 60068-2-27
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
Signal ports
DC Power ports
2.5 kV common, 1 kV differential mode @ 1MHz
Description
Dry Heat
Humidity (Damp
Heat, Cyclic)
Vibration
Shock
Test Levels
± 8 kV
± 8 kV
35 V/m
± 4 kV @ 5 kHz
± 4 kV @ 5 kHz
± 4 kV @ 5 kHz
2.5 kV common mode @ 1MHz
Test Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Db
95% (non-condensing),
55 °C (131 °F), 6 cycles
 
1 g @ 10-500 Hz
 
30 g @ 11 ms