OPERATION GUIDE
P I T H E R M O C O N T R O L P A N E L
Please Refer to Manual for Full Operation and Maintenance Instructions at wallas.com
IGNITION
Press the Power Button for 3 seconds until
the yellow power light will come on. When
you release the button, the yellow heating
light will appear.
Red combustion light will light up when the
burner flame has been ignited and the
combustion has stabilised (approx. in 5 min).
Stove will be fully operational about 10 min
later.
Stove is set to always start in
Manual Mode ready for cooking.
COOKING
In Manual Mode, turn the Temperature/
Power Knob to max. level 6 and begin
cooking. Adjust it to a lower temperature,
if needed, as you would a domestic stove.
When Manual Mode for cooking is
on, the orange Thermostat light is off.
HIGH ALTITUDE MODE
When the device is used 1500 m (4,900 ft) above sea
level, it is necessary to activate the High Altitude Mode
to adjust the combustion.
Start the stove by holding the Power
Button down for 10 seconds.
Yellow heating light will flash 3 times and
then change to a solid yellow light. High
Altitude Mode is now on and the stove
has started the ignition process.
SHUTDOWN
Press the Power Button down for 2
seconds.
Yellow heating light will shut off
immediately.
S t o v e s 8 0 0 D S L , 8 5 D T / N D T , 8 8 D U , X C D u o
I
1.
2.
3.
4.
5.
6.
7.
SUN SWITCH
Sun Switch automatically turns the blower lid
heater off if the temperature remains +3 C (37 F)
above the set level for 1/2 hour due to
temperature increase in weather.
Orange thermostat light will
begin to flash every 30 seconds.
I
Turn the Power Knob slightly to
turn the Sun Switch off
temporarily.
If heating is still needed, turn
I
the device back on manually.
Red combustion light will continue to
I
flash for about 5 minutes, while the
stove is cooling down. Heater cannot
be restarted until the cool down is
completed.
Combustion indicator
Temperature / Power knob
Power button
Power indicator
Thermostat/blower lid indicator
Thermostat sensor
Heating indicator
(IN PI THERMO MODE)
see
ignition

Advertisement

loading

Summary of Contents for wallas 800 DSL

  • Page 1 S t o v e s 8 0 0 D S L , 8 5 D T / N D T , 8 8 D U , X C D u o Please Refer to Manual for Full Operation and Maintenance Instructions at wallas.com...
  • Page 2 Combustion Air Blower Fault Main Blower Fault www.wallas.com All rights reserved. Wallas-Marin reserves the right to change or improve its products and to make changes in the content of this guide without obligation to notify any person or organization See instructional video of such changes or improvements.

This manual is also suitable for:

85 dt85 ndt88 du88 xc duo