Download Print this page
wallas PI Thermo Operation Manual

wallas PI Thermo Operation Manual

Advertisement

Quick Links

OPERATION GUIDE
P I T H E R M O C O N T R O L P A N E L
Please Refer to Manual for Full Operation and Maintenance Instructions at wallas.com
IGNITION
Press the Power Button for 3 seconds until
the yellow power light will come on. When
you release the button, the yellow heating
light will appear.
Red combustion light will light up when the
burner flame has been ignited and the
combustion has stabilised (approx. in 5 min).
Stove will be fully operational about 10 min
later.
Stove is set to always start in Manual
Mode ready for cooking.
COOKING
In Manual Mode, turn the Temperature/
Power Knob to max. level 6 and begin
cooking. Adjust it to a lower temperature,
if needed, as you would a domestic stove.
When Manual Mode for cooking is
on, the orange Thermostat light is off.
HEATING WITH BLOWER LID
Once the stove is fully ignited, lower the blower lid down
until it locks and the device will begin to blow warm air
for cabin heating.
PI Thermo Mode: Set a target temperature (C°/F°)
Manual Mode: Control heating power with knob
Rotate the Temperature/Power Knob to the
desired temperature in PI Thermo Mode
(refer to temperature chart above) or control
heating power with knob in Manual Mode.
Switch between modes by turning the
Temperature/Power Knob back and
forth to min - max - min.
SHUTDOWN
Press the Power Button down for 2
seconds. Yellow heating light will shut off
immediately.
S t o v e s 8 0 0 D S L , 8 5 D T / N D T , 8 8 D U , X C D u o
I
Temperature Chart for
the thermostat in
heater in PI Thermo
Mode for stoves with
heater blower lid:
To switch back to cooking, unlock the lid and push
it back to upward position. Make sure the stove is
in Manual Mode before cooking.
Stove does not operate correctly if it is left in
PI Thermo Mode.
When the PI Thermo Mode is chosen,
the orange thermostat/blower lid light
is on.
In Manual Mode, the light is off.
I
Red combustion light will continue to
flash for about 5 minutes, while the stove
is cooling down. Unit cannot be restarted
until the cool down is completed.
2
3
7
1
5
6
1.
Combustion indicator
2.
Temperature / Power knob
3.
Power button
4.
Power indicator
5.
Thermostat/blower lid indicator
6.
Thermostat sensor
7.
Heating indicator
1: ~ 5 °C (~ 41 °F)
2: ~ 11 °C (~ 52 °F)
3: ~ 17 °C (~ 63 °F)
4: ~ 23 °C (~ 73 °F)
5: ~ 29 °C (~ 84 °F)
6: ~ 35 °C (~ 95 °F)
(STOVES WITH BLOWER LID)
4

Advertisement

loading

Summary of Contents for wallas PI Thermo

  • Page 1 S t o v e s 8 0 0 D S L , 8 5 D T / N D T , 8 8 D U , X C D u o Please Refer to Manual for Full Operation and Maintenance Instructions at wallas.com...
  • Page 2 Combustion Air Blower Fault Main Blower Fault www.wallas.com All rights reserved. Wallas-Marin reserves the right to change or improve its products and to make changes in the content of this guide without obligation to notify any person or organization See instructional video of such changes or improvements.