Fig. 40: Installing The Wall Insert 2; Table 46: Tightening Torque (72002) - ABB Power 845-M Operation Manual

High-pressure stage
Table of Contents

Advertisement

Operation Manual / Power2 845-M / High-pressure stage
9 Disassembly and assembly / 9.13 Installing the wall insert
Fig. 40: Installing the wall insert 2
Part number
Thread and tightening torque
72002
M10x75
30 Nm
Table 46: Tightening torque (72002)
6. Fit a nut (72004) as a safeguard.
7. Remove bracket (90030).
8. Slide in wall insert (77000) as far as it will go.
9. Detach speed measurement cable from provisional holder and insert cable connector
(86515).
10. Fit three studs (72002) again in upper area and tighten.