Details Of Command And Option; Flce /Y - Casio PA-2400W Software Manual

C library manual
Hide thumbs Also See for PA-2400W:
Table of Contents

Advertisement

7.13 Details of Command and Option

Title
This command sets up the device, baud rate, and communication mode used for communication.

If this command is omitted, the default value {IrDA, , } is used.

Any of the parameters can be omitted. If this is done, the default values for each parameter will be used.

Always insert this command directly after the word "FLCE". Placing it in another place will result in a parameter
error.


C Language Interface


Calling Sequence
FLCE /Y={ [<device>], [<baud rate>], [<mode>] }
(Comma must be written and no space allowed. Parameters in [


Parameters


Device
Select either "IrDA" or "COM1".

Baud rate
If "IrDA" is selected – the baud rate setting can not be allowed.
If "COM1" is selected - The following baud rates can be selected for RS-232C communication.
Combinations other than those described above are not permitted and will cause a parameter

error.
Mode
"H" - PA-2400W-to-PA-2400W command specification mode (Session-wait timeout is
1 minute.)
This option is used by one side which specifies the operation command when performing
communication between two PA-2400Ws.

(The FLCE on the communication partner should operate in the idle start mode.)

"I" - Normal mode (Session-wait timeout is infinite.)

Only "H" or "I" can be specified.
If mode specification is omitted, the normal mode with the session-wait timeout set to 1
minute is automatically specified.


Startup Examples

FLCE /Y={COM1, 115200, } /S "\casio\*.dat" "d:\casiodat\"
Communication is performed using the RS-232C port at a baud rate of 115.2 Kbps. (Session-wait timeout
is 1 minute.)

FLCE /Y={, , I} /S "\casio\*.dat" "d:\casiodat\"
Communication is performed through command specification with the device name and the baud rate
are default-set. (Session-wait timeout is infinite.)

FLCE /Y={, , H} /S "\casio\*.dat" "d:\casiodat\"
Communication is performed between two PA-2400Ws through command specification with the device
name and the baud rate are default-set. (Session-wait timeout is 1 minute.)

FLCE /Y={, , I}
Communication is performed in the idle mode with the device name and the baud rate are default-set.
(Session-wait timeout is 1 minute.)

FLCE /Y={, , } /S "\casio\*.dat" "d:\casiodat\"
Communication is performed under the same conditions (with default values) of which "/Y" is omitted.
9600, 19200, 38400, 57600, 115200
Table 7.7
Startup
Idle (including script)
PC (I/O Box)/PA-2400W
Designation of
PC (I/O Box)
Operation command
PA-2400W
Command
Communication Partner
58

FLCE /Y

] can be omitted.)
Session Wait Timeout
1 minute
Infinite
No mode
Mode
specification
Specification, "I"
Mode
specification, "H"
-

Advertisement

Table of Contents
loading

Table of Contents