Table 7.6 List of termination codes
Error Code
Category
Detail
code
code
00h
00h
Normally terminated
DCh to
00h
Normally terminated
F5h
F6h
00h
Normally terminated
F7h
00h
Normally terminated.
F8h
00h
Terminated due to interruption.
01h
00h
Protocol error
02h
80h
File not found
02h
81h
Current directory delete error
02h
82h
File write error
02h
83h
File read error
02h
84h
Read only access error
0Fh
01h
Argument parameter error
0Fh
02h
Argument too long
A0h
10h
Communication port open error
A0h
20h
Line break error or IrDA
duplicate open error
A0h
30h
Session-wait timeout error
Meaning
Normal.
Formatting of drive a:between 'A'
and 'Z' is specified from the
partner station. (For drive letter
definitions, refer to Chapter
7.7 "Method of Describing
Pathname".)
Power-off is specified from the
partner station.
Resetting the power is specified
from the partner station.
Communication is terminated
because the break key is pressed
on the PA-2400W (local station)
or partner station.
Data anomaly (data error
occurred on the communication
line).
Non-existent file is specified.
An attempt has been made to
delete the current directory.
Write to the file is not possible.
Read from the file is not possible.
An attempt has been made to
overwrite or delete the read-only
file.
Incorrect argument description
Argument portion of the
command line is too long
One of the other programs is
using COM1 or IrDA,or FLCE is
already initiated.
Either the cable was unplugged
during communication or the
IrDA connection is broken
(where the PA-2400W is
dismounted from I/O Box).
IrDA port is already open.
Session was not established
within 1 minute of startup.
55
Possible Cause
-
Refer to Chapter 7.5
"Restrictions".
Turn off the power.
Refer to Chapter 7.5
"Restrictions".
Resume communication as
required.
Check the communication
line connection.
Check the specified file or
directory.
Check the objective
directory of deletion.
Check if the file is ready to
be written.
Check if the file is ready to
be read from.
Specify another file name or
cancel the read-only
attribute.
Check the argument
parameter.
Reduce the length of the
argument including FLCE to
255 characters or less.
Terminate the program that
is using COM1 or IrDA.
Check the cable connection
and mounting condition of
the PA-2400W on I/O Box.
Terminate the other
program that is using IrDA.
Check the cable connection
or check if the IrDA is ready
for communication.
Remedy