Industrial Event Camera
Product Specifications
2.4
Electrical Connection
The following connections are located on the sensor.
Connection Assignment
Note
Current Consumption
The maximum input current of the camera is 200 mA over the entire input voltage range with
the heater deactivated. When the heater is activated, the maximum input current is 700 mA.
12
Power supply and digital input connection
M12 plug, A-coded, 4-pin
1
2
4
3
Ethernet interface 10/100 Mbit
M12 socket, D-coded, 4-pin
1
4
2
3
1. Power supply + (18 V DC
... 28 V DC)
2. Digital input
Low: 0 % ... 5 V DC
High: 16 V DC ... 32 V DC
3. Power supply - (0 V)
4. Not used
1. TX+ Ethernet
2. RX+ Ethernet
3. TX- Ethernet
4. TX- Ethernet