Industrial Event Camera
Web Interface
5.3.2

Settings

All camera settings are saved to the SD card in the file ipcam_settings.json. If this file
does not exist or is invalid due to incorrect manual editing, the default settings are loaded and a
message appears at the top of the Settings page.
When settings are saved on the Settings page, the ipcam_settings.json file is created or
overwritten.
Delete this file from the SD card to reset the camera to factory settings. This is only necessary if
the password for the admin user has been forgotten. Otherwise, all settings can be adjusted via
the user interface.
Camera
Setting
Camera name
Rotation
Overlays
Heater
26
Default Setting
Values
-
0 – 255 characters, a
– z, A – Z, 0 – 9, "-";
no "-" as the first or
last character
0 °
0 °, 90 °, 180 °, 270 °
Camera name
-
Date and time
Custom overlay
off
off, low, medium, high Activate and set the heater level
Description
The name of the camera, which
is freely selectable, is displayed
on the start page and can be
superimposed on the camera
stream.
Image rotation. The aspect ratio
remains the same, which
enlarges the image by 90 ° and
270 °.
The activated elements appear
at the top of the camera image.
The overlay is limited to 255
characters and is shortened if
necessary.