9-6 Poor cooling in Refrigerator room
No
Checking flow
1
Check R-Sensor resistance.
<CON7>
※ R-Sensor is determined by
the temperature.
For example, 30㏀ indicates 32°F.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open the fresh food door and Check the
air flow.
4
Check the air temperature.
Cold or not ?
Result & SVC Action
Temperature
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Status
SVC Action
Windy
Go to the 4
Check the F Fan motor
No windy
Check the Damper
(Go to the 5)
Status
SVC Action
Cold
Explain to customer
Check the Compressor
Not cold
And sealed system
- 37 -
Result
38 ㏀
30 ㏀
24 ㏀
19.5 ㏀
16 ㏀