Kenmore 795.72033 Service Manual page 27

Table of Contents

Advertisement

Appliantology.org
8-5 Defrost Heater Error (Er dH)
No
Checking flow
1
Check the Door gasket.
2
Check the Defrost control part.
Fust
M
Def'
3
Input Test 3 Mode.
(Push the button 3 times)
4
Check the Blue(Pin4) to Orange
(Pin9) at CON3 on the main PCB
<CON3>
5
Release the test mode.
push the button 1 times. (normal)
6
Check the Blue(Pin4) to Orange
(Pin9) at CON3 on the main PCB
<CON3>
Result & SVC Action
Part
Result
0 Ω
Fuse-M
Other
34~42 Ω
Def'
Def'
Sensor
Heater
Other
0 Ω
Def'
Heater
sensor
OFF
Result
112 ~ 116 V
0 V
Result
0 V
112 ~ 116 V
- 27 -
SVC Action
Go to the 3
Change Controller Assembly
(Position No.400A )
Go to the 3
Change Controller Assembly
(Position No.400A )
Go to the 3
Replace product
SVC Action
Go to the 5
Replace Main PCB
SVC Action
Explain to customer
Replace Main PCB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.72039795.72032795.72036795.72034