Kenmore 795.72033 Service Manual page 29

Table of Contents

Advertisement

Appliantology.org
8-7 Icing Fan Error (Er IF)
No
Checking flow
1
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
2
Open the refrigerator door and Check the
air flow.
※ While an error code is displayed,
the fan is not working.
3
Check the Connector.
(Frozen caused the PCB short)
4
Check the Fan motor.
(Frozen, Lock, ect.)
5
Check the Fan motor voltage.
(1)Pin1, (2)Pin3, (3)Pin5
Result & SVC Action
Point
(2) ~ (3)
(1) ~ (3)
<CON7>
- 29 -
Status
SVC Action
No windy
Go to the 3,4
Windy
Go to the 5
Result
SVC Action
Below 7 V
Change the PCB
0 or 5 V
Change the motor