Canada. Copyright Statement This Tellabs manual is owned by Tellabs or its licensors and protected by U.S. and international copyright laws, conventions, and treaties. Your right to use this manual is subject to limitations and restrictions imposed by applicable licenses and copyright laws.
Page 7
The 8820 Multi-service Switch Router System Installation manual provides instructions for safely unpacking, installing, powering- up, testing and servicing the Tellabs® 8820 Multi-service Switch Router (MSR). After completing the procedures in this installation guide, you can start managing and configuring the 8820 MSR equipment with the Tellabs®...
Page 8
❑ Chapter 1—Installation Overview —provides a quick glance of the task sequence typically required for installing an 8820 MSR after all components have been removed from the shipping carton, site preparation is completed, and all components have been inspected. ❑...
Page 9
The safety precautions listed in this section represent warnings associated with certain dangers of which Tellabs is aware. You, as the user of this product, must observe these warnings and all other safety precautions necessary to ensure your personal safety as well...
Page 10
The safety ground wire should be a minimum 14 AWG UL listed stranded wire. The wire will need a ring lug attached to the end which connects to the 8820 MSR chassis. The ring lug will be connecting to the 8 x 32 threaded stud and secured in place with a nut provided with the unit.
Page 11
Contact Tellabs Advanced Data Products Technical Support to determine if the Lithium battery is the source of any defective operations on the 8820 MSR, and do not attempt to change the battery without the assistance of authorized, Tellabs service personnel. Please Table 2-2 on page 6 for contact information.
Page 12
Use of controls or adjustments, or performing procedures, other than as specified herein, may result in exposure to hazardous invisible radiation. The 8820 MSR circuit cards can be damaged by static electricity that builds up on work surfaces and on your body. Static is produced by the everyday movement of...
Installation Overview CHAPTER 1 This chapter introduces the task sequence typically required for installing a Tellabs® 8820 Multi-service Switch Router (MSR) after all components have been removed from the shipping crate, site preparation is complete, and all components have been inspected.
Power, on page 4-8 for details. 3. Position, and Cable the 8820 MSR Prior to installing the 8820 MSR in a rack you may need to install the mounting brackets provided with the equipment. Step 1 Install the 8820 MSR, on page 4-3...
System IP Address ❑ IP mask ❑ Gateway IP Address Connect the Local Console to the 8820 MSR, on page 4-15 Connect the local console (computer or terminal server) to a 8820 MSR serial port. Apply and Verify Power, on page 4-16 Power up and perform initial configuration of the system.
Unpacking and Site CHAPTER 2 Preparation This chapter describes the 8820 MSR shipping contents and site preparation requirements, and provides guidelines for preparing the 8820 MSR for installation, in the following sections: ❑ Safety Information, on page 2-2 ❑ Unpacking the 8820 MSR, on page 2-2 ❑...
ESD jack located on the 8820 MSR. Unpacking the 8820 MSR The 8820 MSR arrives in at least two crates, one of which contains the 8820 MSR chassis, and other(s) that contain the Physical Line Modules (PLMs). This section guides you through the unpacking process, in the following topics: ❑...
Inspect the Physical Line Modules (Optional), on page 2-5 8820 MSR Crate Inspection and Disassembly When unpacking the 8820 MSR, you will first disassemble the wood crate, then remove the chassis and accessory box from its internal cardboard carton and plastic wrap.
Page 20
Step 4 Use standard operating procedures (according to your site safety guidelines) to carefully lift the 8820 MSR to and place it on the ground or on a cart for transport to the installation site. Use safe lifting practices when removing the 8820 MSR from the shipping carton.
96-0837-000 Wrist strap strap with 170 plug termination (standard banana plug) Currently the 8820 MSR chassis is shipped loaded with the Physical Line Verify Receipt, on page 2-6 Modules (PLMs). Proceed to the section if you are not inspecting newly purchased PLMs.
Verify Receipt Compare the contents of the shipping container against the packaging list to ensure you have received all components required for installation of the 8820 MSR. If any components (Table 2-2) are missing, contact the...
Site Preparation Use guidelines in this section to ensure that you have the proper tools and operational conditions on hand for installing the 8820 MSR. This section describes how to prepare the 8820 MSR installation site, in the following sections: ❑...
Hand crimping tool Molex # 63811-1100 or equivalent. Rack Requirements Mounting brackets are shipped pre-assembled on the 8820 MSR ready to attach to a Install the 8820 MSR, on page 4-3 standard 19-inch rack. See for detailed mounting instructions. The optional 23-inch bracket is available and is shipped separately.
1280 BTU per hour - AC powered unit 1024 BTU per hour - DC powered unit The 8820 MSR must be installed in a restricted access location, as defined in U.S. Articles 10-116, 10-117, and 10-118 of the National Electrical Code ANSI/NFPA 70, and as advised...
Tellabs 8820 Multi-service Switch Router System Installation Power Requirements Each 8820 MSR is provided as either an AC- or DC- powered model. All 8820 MSR products must be hardwired to earth ground. The chassis earth ground point is an 8x32 lug and lock nut located on the rear of the chassis.
Tellabs 8820 Multi-service Switch Router System Installation AC Power The 8820 MSR AC model does not accommodate redundant power feeds. The AC model is equipped with a standard IEC-320 AC receptacle on the rear panel. The unit’s single AC Table 2-8...
Table 2-9 lists the PLM types, product codes, and PLM descriptions for the PLMs that requires optical network cables for the 8820 MSR installation. Be sure to obtain these cables before proceeding with your installation. For more information regarding the specifications...
Page 29
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Table 2-9 PLM Optical Network Cables PLM Type PLM Product Code PLM Description Cable Type and Connector Per Port Single mode, LC 81.8800-PLM003T-20 OC-3/STM-1 MST SMF IR connector OC-3 OC-3/STM-1 MST SMF Single mode, LC 81.8800-PLM003T-30...
Fast Ethernet PLM product code, description, cable type and Table 2-11 connector per port needed for an 8820 MSR installation. lists the spares and accessories that can be obtained for the Fast Ethernet PLM. Installation of a Fast Ethernet...
Tellabs 8820 Multi-service Switch Router System Installation DS3 Clear Channel and Channelized PLM Details Table 2-12 contains the DS3 clear channel and channelized PLM details for an 8820 MSR Table 2-13 installation. lists the spares and accessories that can be obtained for the DS3 PLM.
Page 32
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation 2-16 Unpacking and Site PreparationDS3 Clear Channel and Channelized PLM Details Power Requirements...
Page 33
Equipment Overview CHAPTER 3 This chapter describes the 8820 MSR hardware components, in the following sections: ❑ 8820 MSR Chassis, on page 3-2 ❑ Physical Line Modules, on page 3-7 ❑ PLM Blank Panel, on page 3-8 Tellabs 8820 Multi-service Switch Router System Installation...
5.25-inches (133mm), or three rack units (RUs), in industry-standard racks. Figure 3-1 8820 MSR Chassis, Front Front Panel The front panel of the 8820 MSR provides access to system ports and status indicators, and (Figure 3-2) includes the following components Main port AUX port...
(AC power) Alarm LEDs The 8820 MSR alarm LEDs indicate severity of problems detected by the system. Severity is immediately apparent as a result of interpreting the LED colors shown in the CRT, MAJ, (Table 3-2) and/or MIN LEDs...
(Minor) ACO Button The 8820 MSR alarm cutoff (ACO) button provides the means to silence audible alarms as well as activate hardware LED tests. Briefly pressing the button silences the current audible alert, whereas pressing and holding the button down for a few seconds activates the LED tests.
Figure 3-3 8820 MSR Fan Module Assembly Power Panels AC or DC power is connected to the 8820 MSR through connectors located at the rear of the chassis, as described in the following sections: ❑ 8820 MSR AC Model Power Panel ❑...
Page 38
RESTRICTED ACCESS AREA. Figure 3-5 8820 MSR DC Connector Panel The 8820 MSR accommodates redundant power feeds. The unit can operate on only one Table 2-6 feed that meets the minimum requirements as presented in . If the unit is installed in a redundant power application, both feeds must be connected and compliant with the minimum requirements.
The line card can detect the presence of a PLM and the type of PLM in each of the four module interface positions. The 8820 MSR PLMs are available in various configurations, as described in the section Optical PLMs and Power Requirements, on page A-4 All PLMs are hot-swappable.
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation PLM Blank Panel The PLM blank panel maintains proper airflow through the system. All system slots not occupied by PLM must be populated with a blank panel. Equipment Overview PLM Blank Panel...
Load the Chassis (Optional), on page 4-11 ❑ Connect 8820 MSR Alarm Outputs, on page 4-14 ❑ Connect the Local Console to the 8820 MSR, on page 4-15 ❑ Apply and Verify Power, on page 4-16 ❑ System Boot Up, on page 4-17 ❑...
ARNING inside the 8820 MSR. Do not apply power to the 8820 MSR until you complete all installation tasks in this chapter. Be sure that the circuit breakers located at the rear of the 8820 MSR enclosure are in the OFF position.
The 23-inch mounting brackets can only be installed in the mid-mount position. If the rack is to be populated by more than one 8820 MSR unit, select a height consistent with the local practices for partially-populated racks.
With the help of an assistant, lift and align the unit into pace at the rack. One person must be positioned at the rear side of the rack to balance the 8820 MSR while the other person balances the front and secures the unit to the rack.
With the help of an assistant, lift and align the unit into place at the rack. One person must be positioned at the rear side of the rack to balance the 8820 MSR while the other person balances the front and secures the unit to the rack.
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Installing the 8820 MSR into an Enclosed Cabinet Mount the four brackets that hold the 8820 MSR in an enclosed cabinet and proceed as follows: Step 1 If possible remove the side panels from the enclosed cabinet. This will allow side access when installing the 8820 MSR chassis.
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Connect Power This section describes how to connect an AC or DC power source for the 8820 MSR, in the following sections: ❑ Connecting AC Power, on page 4-8 ❑ Connecting DC Power Feeds, on page 4-9 The 8820 MSR supports auto-sense for 110/60 Hz or 220 VAC/50 Hz.
Figure 4-5 Connecting DC Power Feeds The 8820 MSR DC model provides redundant (A and B) power feeds at -40 VDC to -60 VDC. The unit can operate on only one feed or both feeds, as long as the minimum power...
Page 50
DC power kit. Install the contacts per the manufacturer’s instructions. The DC power kit allows you to prepare the cabling end that connects to the 8820 MSR chassis by letting you decide whether the red or black cable is (Figure 4-7) inserted on either PIN 1 or PIN 3 of the power connectors .
8820 MSR equipment. The 8820 MSR comes fully loaded with PLMs on first shipment. The additional 8820 MSR PLMs are packed in a separate shipping container. Install them in the chassis after you mount the unit in the rack. Figure 4-8...
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Inserting the PLMs To install a PLM into a slot use the following procedure: Step 1 Locate the slot for the PLM. Step 2 Gently slide the PLM into that slot.
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Install Blank Panels Blank panels are provided with the 8820 MSR. All unused PLM slots must be covered with (Figure 4-10) a blank panel Step 1 Insert the PLM blank panel into the empty 8820 MSR module slot.
Tellabs 8820 Multi-service Switch Router System Installation Connect 8820 MSR Alarm Outputs The 8820 MSR chassis has a DB-25 connector for connections to an external alarm system. Separate sets of alarm relay contacts are provided for the following alarm severities: ❑...
Tellabs 8820 Multi-service Switch Router System Installation Connect the Local Console to the 8820 MSR The 8820 MSR console port provides access to the Tellabs® Multi-service Operating System (OS), which is the command line interface (CLI). Use the modular, null-modem (crossover)
Check the distribution circuit breakers or fuses Step 2 Turn on the 8820 MSR power switch on the rear panel to apply power to the unit. Step 3 Verify power is applied by observing the PWR LED marked A on the front panel...
If modifications (not recommended) are required at Stage 1 or Stage 2 boot script, proceed Setting Boot Parameters, on page B-1 to the guidelines provided in the section entitled Log Into the 8820 MSR Console Interface When you connect to the 8860 Multi-service Switch Router and establish a management (Figure 4-12) session, the console interface login prompt is presented .
CLI prompt: logout 8820# Change the Default Password When the 8820 MSR switch is first powered up it provides two default logins at the CLI for (Table 4-2) two user types—root and admin Table 4-2 Default User Login Detail...
Page 59
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation --------------------------------------------------------- | For security reasons, please log in as root to change | | all default passwords. SNMP access will not be | allowed until the changes have been made. -------------------------------------------------------------...
8820# enable config protocol ip route 24.0.1.0/24 24.0.1.1 Connect the Ethernet (IP Management) Port When you obtained the 8820 MSR, you also received a cable to connect the router to your management IP network, using the 8820 MSR Ethernet port. To connect the 8820 MSR switch to a management IP network, connect the cable from the 8820 MSR Ethernet port to a management IP network port.
This appendix summarizes the physical, electrical, and environmental specifications for the 8820 MSR. ❑ 8820 MSR Physical Specifications, on page A-2 ❑ 8820 MSR System Management and Alarm Specifications, on page A-2 ❑ DC Power Requirements, on page A-2 ❑ AC Power Requirements, on page A-3 ❑...
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation AC Power Requirements Table A-3 AC Power Requirements Characteristic Detail ❑ AC chassis Single AC power cord input ❑ Voltage 85 VAC to 264 VAC ❑ Frequency 50 Hz to 60 Hz ❑...
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Optical PLMs and Power Requirements The following sections provide the optical power requirement specifications for all SONET/SDH PLMs: ❑ OC-3 PLMs, on page A-5 ❑ OC-12 PLMs, on page A-6 ❑...
Tellabs 8820 Multi-service Switch Router System Installation OC-3 PLMs (Figure A-1) The OC-3/STM-1 PLM is a four-port STS-3/STM-1 module that can be plugged into any of the four slots on a 8820 MSR. Faceplate Detail ❑ Four independent 155.52 Mbps SONET/SDH STS-3/...
Page 66
Tellabs 8820 Multi-service Switch Router System Installation OC-12 PLMs (Figure A-2) The OC-12/STM-4 PLM is a four-port STS-12/STM-4 module that can be plugged into one of the four slots on a 8820 MSR. Faceplate Detail ❑ Four independent 622.08 Mbps SONET/SDH STS-12/...
Page 67
Tellabs 8820 Multi-service Switch Router System Installation OC-48 PLMs (Figure A-3) The OC-48/STM-16 PLM is a single-port STS-48/STM-16 module that can be plugged into any of the four slots on the 8820 MSR. Faceplate Detail ❑ Four independent 2.488Gbps SONET/SDH STS-48/STM-...
Page 68
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Other PLMs The following sections provide faceplate descriptions and power requirements for Ethernet and DS3 PLMS. ❑ GigE PLMs, on page A-9 ❑ Fast Ethernet PLM, on page A-10 ❑ DS3/E3 Clear Channel PLM, on page A-11 ❑...
GigE PLMs (Figure A-4) Each Gigabit Ethernet (GigE) PLM is a four-port Gigabit Ethernet module that can be plugged into any of the four slots of a 8820 MSR. Faceplate Detail ❑ Four independent 1000 Base-SX (550 meters), 1000 Base- LX (10 Km), or 1000 Base-LH (80 Km) ports for Gigabit Ethernet over fiber, with LC or MT-RJ connectors.
Fast Ethernet PLM (Figure A-5) Each Fast Ethernet 10/100 PLM is a 24-port line module that can be plugged into any of the four slots of an 8820 MSR. Faceplate Detail ❑ Two Mini-RJ receptacles, each of which support 12...
6 port T3/E3 for the Tellabs 8800-series Multi- service Switch Routers. A DS3 PLM may be used in any open PLM slot on any Tellabs 8800-series MSR. The DS3 PLM supports 6 ports of T3 or E3 by using six pairs of SMB connectors.
Each DS3 channelized PLM is a 6 port T3/E3 for Tellabs 8800-series Multi- service Switch Routers. A DS3 PLM may be used in any open PLM slot on any Tellabs 8800-series MSR. The PLMT3E3-10 supports 6 ports of channleized DS3 with support for any valid combinations of nxDS1 or nxDS0 by using six pairs of SMB connectors.
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Safety and Compliance Specifications Table A-9 Safety and Compliance Specifications Characteristic Detail ❑ CSA C22.2 No. 950 Safety ❑ UL 1950, 3rd Edition ❑ EN 60950 ❑ EN 60825-1/2 ❑ FCC Part 15 class A ❑...
DB9-to-RJ45 Connector Adapters Table A-11 lists the pin-to-pin cross-connections of the two RJ-45 female-to-DB-9 female connector adapters furnished with the 8820 MSR. Use these adapters when connecting a local console to the system. Table A-11 DB-9 Female-to-RJ-45 Female Adapter Pin Cross-Connections...
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation External Alarm Connector The DB-25 connector supports three visual alarm outputs, three audible alarm outputs, and Table A-12 an ACO input. Pinouts for the external alarm interface are shown in Table A-12...
Ethernet (IP Management) Connector The Ethernet (ENET) connector is a 10/100 Base-T Ethernet RJ-45 connector. This port provides networks management access to the 8820 MSR. Table A-13 details the pinouts for the 8820 MSR management port. Table A-13 Management Connector Pinouts Signal TxD + (out) TxD –...
Page 79
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Port Densities Table A-14 lists the port densities for the 8820 MSR PLMs. Table A-14 PLM Port Densities Physical Interfaces Per PLM Per 8820 MSR Per 7-ft Rack OC-48/STM-16 OC-48c/STM-16c OC-12/STM-4...
APPENDIX B Parameters The Multi-service Operating System is pre-installed and ready for system configuration after powering up the 8820 MSR. During system bootup, check to ensure that the hardware LEDs are reporting proper status. The client IP address, IP mask, and IP gateway address must exactly match those configured on the IP management port.
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Viewing and Modifying Boot Parameters During an initial boot up, the console screen displays the boot up script from the 8820 MSR. Use the following steps to view and modify the boot parameters: Step 1 Press the ESC key to interrupt the boot script, and to present the M prompt.
Page 83
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation M>dc Node address Client IP address ......: 10.8.4.63 Network IP mask ......: 255.255.0.0 Gateway used by the management Ethernet interface for connection to any Gateway IP address ......: 10.8.0.1 external non-directly connected management device.
Page 84
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Step 5 Use the boot command to restart the normal booting sequence, and wait for the CLI banner to display. M>boot Vivace Networks First Stage Boot Loader Version 1.2.0 Copyright (c) 1999-2002 Vivace Networks, Inc.
Page 86
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation Login: root Default user name login: root Default password: viva-private Password: |----------------------------------------------------------------------------------------------| | CHANGE ALL DEFAULT PASSWORDS IN 5 MINUTES, OTHERWISE | YOUR SESSION WILL BE TERMINATED |----------------------------------------------------------------------------------------------| Change password for: root...
Page 87
2-10 environmental requirements 2-9 equipment racks power requirements 2-10 cable ESD grounding strap 2-2, 2-7 bundling 2-7 identification tags 2-7 COM port configuration 4-15 Fast Ethernet PLM CP module 4-11 Tellabs 8820 Multi-service Switch Router System Installation INDEX-1...
Page 88
PN 76.8820IM30-A Tellabs 8820 Multi-service Switch Router System Installation cable details 2-14, 2-15 faceplate and power faceplate and power requirements A-7 requirements A-10 port density A-19 port density A-19 product code and cable fatality precautions 3-xii requirements 2-12 fuses 2-10...