ELECTRICAL WIRING
11.4 ELECTRICAL WIRING FOR OUTDOOR UNIT
11.4.1 RAS-(4-6)FS(V)NME
Detail of terminal block for power source and
control circuit.
Electrical box
11.4.2 For RAS-(8-12)FSXNME
38
PMML0511 rev.1 - 06/2019
RAS-(4-6)FSVNME: 1N~ 230V 50Hz
Screw (M5)
Screw (M4)
Power
Communication
source
wiring
wiring
Wind the wire 3
times
Cable tie
Ring core
Earth wire
Yellow
Only for RAS-(4-6)FSVNME: Cord clamp (for fixing power
source wiring and control circuit wiring)
Cord clamp (for fixing power source wiring and control
circuit wiring)
Electrical box
Detail of terminal
block for power
source and control
circuit.
3N~ 400V 50Hz
Power
source
wiring
Cord clamp (for fixing power source
wiring and control circuit wiring)
RAS-(4-6)FSNME: 3N~ 400V 50Hz
Earth terminal
Wind the wire 4
times
Cable tie
Power
source wiring
Ring core
Green
Screw (M3.5)
1
2
Control wiring
Screw (M5)
Earth
terminal
R
S
T
3
MP
N
Earth wire
Screw (M5)
Screw (M4)
Earth
terminal
R
S
T
MP
3
N
Control
wiring
Earth wire