For Natural Gas Connection; Transformation From Natural Gas To Lpg And From Lpg To Natural Gas - Kernau KGH 6464 User Manual

Gas and electric cooktop copper/gun metal
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 28

FOR NATURAL GAS CONNECTION

WARNING
Natural gas connection should be done
by authorized service. For natural gas
connection, place gasket in the nut at the
edge of natural gas connection hose. To
install the hose on main gas pipe, turn the
nut. Complete the connection by making
gas leakage control.
TRANSFORMATION FROM NATURAL GAS TO LPG AND FROM LPG TO NATURAL
GAS
1.
Turn off gas and electricity of the cooktop. If your cooktop is hot, wait for cooling down.
2.
For injector change, use a screwdriver whose edge is as the figure 1.
3.
As seen in figure 2, demount burner lid and burner of the cooktop and ensure visibility of
injector.
4.
Remove injector by turning as shown in figure 3 with screwdriver and replace it with a new
one.
Fig. 1
5.
After that, detach control switches of the cooktop. Make setting by turning the screw in the
middle of gas cocks with a small screwdriver in the manner shown in the following picture. To
adjust flow rate screw, use a screwdriver having suitable dimension. For LPG, turn the screw
clockwise. For natural gas, turn the screw one time counter clockwise. At low position, length
of normal flame should be 6-7 mm. For the last control, check out whether flame is open or
closed. Setting of your appliance may differ according to the type of gas cock used.
Fig. 2
Fig. 4
Fig. 5
37
Main gas pipe
Gasket
Nut
Natural gas
Connection hose
Fig. 3