Download Print this page
Zamel exta free RZB-01 Manual Instruction

Zamel exta free RZB-01 Manual Instruction

Wireless control kit - lighting

Advertisement

Quick Links

CoNNECtioN
CAPACitY
750W
500W
250W
375W
APPLiCAtioN
1-channel radio flush receiver ROP-01
operates as a receiver of 8-channel
remote controller P-256/8 and of
2-channel button radio transmitter
RNK-02 (light sources switch on/switch
off control). The above mentioned
The ZAMEL company
transmitters can also control operation
devices which are
of radio lighting switch RWL-01
characterised with this sign
and remote control socket RWG-01.
can cooperate
with each other.
WARRANtY CARD
There is 24 months guarantee on the product
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-
TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting
from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device
in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy
between the goods and the contract.
salesman stamp and signature, date of sale
MouNtiNG
1. Disconnect power supply by the phase fuse,
the circuit-breaker or the switch-disconnector
combined to the proper circuit.
2. Check if there is no voltage on connec-
tion cables by means of a special measure
equipment.
3. Connect the cables with the terminals in ac-
cordance with the installing diagram.
4. Install ROP-01 device in installation cable
box.
5. Switch on the power supply from the mains.
RNK-02 FuNCtioNiNG, MouNtiNG
By pressing the button, the transmitter sends
a signal with 868,32 MHz frequency which con-
trols EXTA FREE receivers. Device program-
ming procedure (adding a transmitter to
a receiver's memory) is described in par-
ticular EXtA FREE manual instructions.
The device range (up to 250 m depending on
a receiver) can be increased by means of a re-
transmitter or few RTN-01 retransmitters. The
device can be mounted in any place by means
of double-sided adhesive tape or wall plugs
5 x (3 x 30) mm.
Mounting by means of wall plugs:
1. Remove the button - to do it press the but-
ton on one side, and on the other side put
a screwdriver into a slot and lift up the button.
2. Find a place on the wall to mount the transmit-
ter, make two holes corresponding mounting
holes from the transmitter's base.
3. Set wall plugs in the holes.
4. Fix the base by means of screwing screws
into wall plugs.
5. Place the button again.
BAttERY CHANGE
Battery discharge status is signalled by sev-
eral LED red diode flashes during transmis-
sion time.
1. Remove the button (as in point 1 of mounting).
2. By means of a screwdriver lever up the
printed-circuit board releasing the bottom latch
(Fig. 2), and remove it from the base.
3. Remove the battery from the latch.
4. Mount a new battery. Watch battery polari-
sation marked on the latch. Wrong battery
mounting may cause device damage.
5. Put the removed printed-circuit board back in
the base.
6. Put back the button.
CAutioN: While changing the battery,
it is suggested to press any of the buttons
for about 5 seconds before putting it into
a latch. Next press transmission button sev-
eral times to check its operation. if the trans-
mitter does not work properly repeat the bat-
tery change procedure.
RZB-01 WIRELESS CONTROL KIT - LIGHTING
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: marketing@zamel.pl
DEsCRiPtioN
tECHNiCAL DAtA
RZB-01 set includes radio receiver
ROP-01 used in flush and surface mo-
unting and RNK-02 transmitter, battery
powered, can be mounted in any place.
The set gives comfortable solution used
to control lighting and other receivers re-
motely.
Nominal power consumption:
Number of operation modes:
FEAtuREs
● complete
set
of
wireless
control
Maximum number of transmitters:
(2–channel button radio transmitter
RNK-02 and 1-channel bistable radio
receiver ROP-01),
● light operation control and other re-
Optic signalling of transmitter's operation:
ceivers control,
● receivers are easily installed in an
Relay contacts parameters:
electric-light fitting or in Ø60 mm junc-
tion box,
Number of terminal clamps:
● five operation modes: switching on
Section of connecting cables:
mode, switching off, monostable, bi-
Ambient temperature range:
stable, time (switch off delay),
● wide range of operation (up to 180 m),
● operation is optically signalled,
● low current consumption, possibility of
constant work,
● possibility of widening operation range
by means of RTN-01 retransmitter.
The device is designed for
single-phase installation and
must be installed in accord-
ance with standards valid in a
APPEARANCE
particular country. The device
should be connected accord-
CAutioN!
ing to the details included in
Relay output terminals
this operating manual. Installation, connection
(12, 11, 14)
and control should be carried out by a qualified
electrician staff, who act in accordance with the
service manual and the device functions.
Input (supply) terminals (L, N)
In case of casing dismantling an electric shock
may occur, and the guarantee is lost then. Be-
fore installation make sure the connection ca-
bles are not under voltage. The cruciform head
Optic signalling of receiver's operation
screwdriver 3,5 mm should be used to instal the
Programming buttons
device. Improper transport, storage, and use of
the device influence its wrong functioning. It
Optic signalling of transmitter's operation
is not advisable to instal the device in the fol-
lowing cases: if any device part is missing or
the device is damaged or deformed. In case of
improper functioning of the device contact the
Push-button
producer.
The symbol means selective collecting
of electrical and electronic equipment.
It is forbidden to put the used
equipment together with other waste.
MANUAL INSTRUCTION
ZAMEL Sp. z o.o.
RNK-02
ROP-01
Input (supply) terminals:
-
Input rated voltage:
3 V (CR2032 battery)
Battery life:
3 ÷ 5 years
Input voltage tolerance:
-
-15 ÷ +10 %
Nominal frequency:
-
-
-
Number of channels:
2
Transmission:
radio 868,32 MHz
Coding way:
unidirectional
Coding:
addressing transmission
-
Range:
up to 250 m in the open area
up to 230 m in the open area
Time adjustment:
-
1 s ÷ 18 hours (every 1 sec.)
LED red diode
Relay output clamps:
-
-
1NO/NC 5A / 250V~ AC1 1250 VA
-
-
do 2,5 mm
-10 ÷ +55
C
o
Operating position:
free
Casing mounting: wall plugs, double-sided adhesive tape
installation cable box Ø60 mm
Casing protection degree:
IP20 (EN 60529)
Protection level:
III
Overvoltage category:
-
Pollution degree:
2
Surge voltage:
-
1 kV (EN 61000-4-5)
Dimensions:
90 x 80 x 11,5 mm
47,5 x 47,5 x 20 mm
Weight:
0,038 kg
ETSI EN 300 220-1
EN 60669, EN 60950
Reference standard:
ETSI EN 300 220-2
L, N
230 V AC
-
50 / 60 Hz
0,29 W
5
1
32
12, 11, 14
5
2
II
II
0,043 kg
EN 61000
VER. 003_20.05.2011

Advertisement

loading

Summary of Contents for Zamel exta free RZB-01

  • Page 1 TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting producer. from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);...
  • Page 2 RoP-01 oPERAtioN tiME PRoGRAMMiNG ROP-01 can operate in five modes: MoNostABLE BistABLE sWitCH oN tiME the relay operates only (one push-button) the the device switches on the device switches while pressing transmit- device changes relay after pressing the push- off according to the ter’s push-button.
  • Page 3 Power Management IC Development Tools Click to view products by manufacturer: Zamel Other Similar products are found below : EVAL6482H-DISC EVAL-AD5522EBUZ EVAL-ADM1060EBZ EVAL-ADM1073MEBZ EVAL-ADM1166TQEBZ EVAL- ADM1168LQEBZ EVAL-ADM1171EBZ EVAL-ADM1276EBZ EVB-EN5319QI EVB-EN5365QI EVB-EN6347QI EVB-EP5348UI MIC23158YML EV MIC23451-AAAYFL EV MIC5281YMME EV 124352-HMC860LP3E ADM00513 ADM8611-EVALZ ADM8612- EVALZ ADM8613-EVALZ ADM8615-EVALZ ADP1046ADC1-EVALZ ADP1055-EVALZ ADP122-3.3-EVALZ ADP130-0.8-EVALZ...