Maintenance; Cleaning Process; Vacuum Filter Maintenance - probst AIRLIFT ALX-120 Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22

Maintenance

6
Maintenance
REPAIRS:Repairs to
the appliance may only be carried out by persons who have the necessary knowledge and skills.
Only original spare parts may be used. Non-compliance will invalidate the warranty.
The only parts to be serviced on site are filters, hoses and seals as well as the associated equipment. All work
must only be carried out when the unit is de-energised and shut down!
Generally: Switch off the mains switch and disconnect the power cable plug at the vacuum generator and
ensure that it is not unintentionally reconnected!
6.1

Cleaning process

Clean the vacuum generator (backpack suction cup), carry handle and handles with a damp towel.
If the disposable paper filter is heavily soiled ❶ (or if performance is lost), remove and replace it.
Remove the permanent fabric filter (with rubber seal) ❷, empty it or wash it if necessary. Clean the rubber seal, then
reinstall it.
Clean the foam suction plate seal if necessary (by hand with soap and water).
Cleaning the back carrying harness (by hand) if necessary.
6.2

Vacuum filter maintenance

Switch off the mains switch and unplug the vacuum generator.
Open the vacuum cover by releasing the locks and remove the cover.
Check disposable paper filter ❶. Change if dirty or wet.
Dispose of the used disposable paper filter. Do not reuse disposable paper
filters ❶ as this will affect performance.
Check the permanent fabric filter (with rubber seal) ❷ and the seal. Clean by
shaking out or carefully washing by hand.
Wipe the rubber seal clean (with a damp cloth). Replace the rubber seal only
when it is completely dry.
52600018
15 / 17
GB

Advertisement

Table of Contents
loading

Table of Contents