Security

2
Security
WARNING!
Concrete slabs, natural stones or tiles (referred to as load in these operating instructions) are the only
materials designed for handling the AIRLIFT. The material is held by a vacuum and drops immediately when
the power supply is interrupted.
2.1

Personal protective equipment required

Protective clothing
Protective gloves
Safety shoes
2.2

Operational safety

Not allowed for overhead lifting- use only near the ground; less than 120 cm (4 ft.).
Remove standing water from the surface of the load before using the unit.
Always use a power source protected by a ground fault interrupter (GFI) and ensure that it is NOT disconnected during
use of the device.
Do not attempt to hold the AIRLIFT in a vertical position.
Exceeding the maximum load capacity (WLL) of the unit (120 kg / 265 lbs) and the optional suction plates is
prohibited!!! Danger: Falling down of the load!
Some of the suction plates that can be attached to the unit reduce its load capacity (WLL).
The maximum permissible load capacity (WLL) is indicated on each suction plate, this must NOT be exceeded!!!
Only suction plates approved for the unit and from the manufacturer Probst may be used!
Never pull the sucked-in load on the handle of the AIRLIFT diagonally (always only vertically upwards).
Do not attempt to lift or force loose a trapped or stuck load.
Do not release the suctioned load until the load (e.g. stone slab) is completely settled on the ground.
Do not reach under the suspended load, serious injuries can result.
Do not operate in rain, thunderstorms, snow or black ice.
Do not operate near explosive materials.
Do not look into the suction hose opening when AIRLIFT is switched on (risk of eye injury).
Only connect the power supply after complete assembly/conversion immediately before starting work!
2.3

Ambient temperature

HEAT: Do not use at temperatures above 40°C (105°F).
COLD: Do not use at temperatures below 0°C (32°F).
Switch off the unit when not in use to avoid overheating.
2.4

Electrical safety instructions

Use at least a 3-core extension cable with a thickness of 12.
Always use a circuit protected by a ground fault interrupter (GFI).
Ensure that the power cannot be disconnected during operation.