User Manual
In order to remove the brewing piston,
1. Remove the fastening pin.
2. Pull up on the piston.
3. In order to completely disassemble the
piston, remove the fastening clip.
Adjustments and regulation
5.4.2.-
Adjusting the coffee dosage. The grinder is time-controlled. The default dosage is
6.5g.
Use the 315 function to change the grinding time and the dosage, adjusting the time of
the desired services.
To adjust the grind. The grinder leaves the factory adjusted at the optimum grinding
position.
Machine with EL60 grinder. move the control lever attached to the upper crown to the
desired setting.
Set at 1 provides the finest grind and the grain size increases as the setting increases.
The coffee dosage decreases at the lowest setting and increases at the highest setting.
Machine with M03 grinder. If a finer grind is desired,
the adjuster can be moved one or two positions while
the grinder motor is running in order to prevent the
grinding
wheels
coffee.The grinder adjustment knob (M) can be found
at the top of the unit. Use it to adjust the degree of
grind desired for the coffee
Verify that the dosage is correct whenever
an adjustment is made and perform a few
coffee services to ensure proper operation.
from
becoming
blocked
- 26 -
Fig. 13.1
M
with
Fig. 13.2
ZENSIA
Need help?
Do you have a question about the Zensia and is the answer not in the manual?