Parameter Mode
DESCRIPTION
PARA
FACTORY
.
.
1
186°F
maximum supply temperature CH
2*
00
type of CH installation:
radiators with large surface areas or underfloor heating as additional heating:
T max. supply 158°F K factor heating curve 1.8; gradient 10°F/min; gear differential 10°F
under floor heating with radiators as additional heating:
T max. supply 140°F; K factor heating curve 1.5; gradient 8°F/min; gear differential 8°F
full under floor heating:
T max. supply 122°F; K factor heating curve 1.0; gradient 6°F/min; gear differential 6°F
3
max.
maximum power CH in kW (.. x3415 = .. BTU/hr)
4*
00
control principal with on / off thermostat:
100 % on / off thermostat
100 % on / off weather dependant
5*
2.3
heating curve K-factor (see also heating curve graph)
6*
1.4
heating curve exponent (see also heating curve graph)
7*
14°F
heating curve climate zone (see also heating curve graph)
10*
0°F
fine adjustment heating curve day temperature
11*
0°F
fine adjustment heating curve night temperature
14
10°F/min.
gradient speed °F/min.
15*
00
Booster after night decrease*:
no
yes
23
26°F
Frost Temperature
27
32°F
Minimum T-set CH
31
132°F
DHW temperature
36
20
Type of three way valve DHW fascility
VC 2010 / VC 8010
Flowswitch
43
max.
Maximum power DHW in kW (.. x3415 = .. BTU/hr)
49
100%
Maximum pump capacity heating
73
0
Altitude and venting CFT. See chapter 6.7.7
89
00
Address
No function
Bus thermostat
90
01
Display reading
°C and Bar
°F and PSI
.
.
Info Mode
INFO
DESCRIPTION
FACTORY
.
.
1
°F
supply water temperature T1
4
°F
return water temperature T2
5
°F
DHW temperature T3
7
°F
outdoor temperature T4
8
°F
flue gas temperature T5 (optional sensor)
16
%
actual power in %
17
kW
actual power in kW (.. x3415 = .. BTU/hr)
18
kW
actual load in kW (.. x3415 = .. BTU/hr)
20
indication bus communication
21
GJ
consumption total in GJ (.. x 33 = .. m3)
22
GJ
consumption CH in GJ (.. x 33 = .. m3)
23
GJ
consumption DHW in GJ (.. x 33 = .. m3)
24
h
total number of burner run hours
25
h
number of burner run hours CH
26
h
number of burner run hours DHW
32
h
total number of hours counter
37
h
total number of run hours pump CH and DHW
46
h
within how many hours is service required
.
.
.
.
.
RANGE
.
68 - 186°F
01 DO NOT USE
02
03
04
min-max
00
01
0.2 - 3.5
1.1 - 1.4
-4 - 32°F
-8 to 10°F
-8 to 10°F
0 - 28°F/min.
00
01
-4 to 50°F
0 - 158°F
68 - 176°F
x0
2x
min-max
100 %
0 - 100
-01
00
00
01
.
RANGE
.
.