Advertisement

Quick Links

Operation and
Maintenance Documentation
ACR PRO – AIR CURTAINS
Type : (ACR Pro)
ACR Pro 1500H
ACR Pro 2000H
ACR Pro 1500C
ACR Pro 2000C
ACR Pro 1500E
ACR Pro 2000E
www.pakole.com
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACR PRO and is the answer not in the manual?

Questions and answers

Summary of Contents for Pakole ACR PRO

  • Page 1 Operation and Maintenance Documentation ACR PRO – AIR CURTAINS Type : (ACR Pro) ACR Pro 1500H ACR Pro 2000H ACR Pro 1500C ACR Pro 2000C ACR Pro 1500E ACR Pro 2000E www.pakole.com...
  • Page 2: Table Of Contents

    Acr Pro air curtains Contents Table of Contents GENERAL AND SAFETY PRINCIPLES �������������������������������������������������������������� 3 PURPOSE OF THE DEVICE �������������������������������������������������������������������������������� 4 BASIC TECHNICAL PARAMETERS ������������������������������������������������������������������� 4 DIMENSION ��������������������������������������������������������������������������������������������������������� 5 HEAT OUTPUT RANGES ������������������������������������������������������������������������������������� 6 ASSEMBLY ����������������������������������������������������������������������������������������������������������� 7 CONTROLLER INSTALLATION ������������������������������������������������������������������������ 9 ELECTRICAL CONNECTION DIAGRAMS ��������������������������������������������������������...
  • Page 3: General And Safety Principles

    . Before starting the device be sure to read the Manual carefully. The ACR Pro air curtains are delivered ready-to-use in a cardboard package that is to protect from any mechanical damages. The pack- age consists of: the device, the Manual (Operation and Maintenance Documentation) and the Guarantee. If the optional automatic control ordered, it shall be delivered in a separate package.
  • Page 4: Purpose Of The Device

    In summers, the curtains may be used as cooling devices preventing the entry of hot air from outside as well as air pollutants. The ACR Pro industrial air curtains are designed to protect against heat losses in the gateways of buildings of medium and high capacity especially such as the followings: •...
  • Page 5: Dimension

    Acr Pro air curtains Operation and Maintenance Documentation DIMENSIONS ACR Pro 1500H, ACR Pro 1500E, ACR Pro 1500C ACR Pro 2000H, ACR Pro 2000E, ACR Pro 2000C...
  • Page 6: Heat Output Ranges

    Air curtains with electric heater ACR Pro 1500E and 2000E ACR Pro industrial air curtians are equipped with modern and safe solution based on PTC electric heaters. PTC are thermistors which means that along with the temperature increase the resistance of the heating element increases as well.
  • Page 7: Assembly

    They must be assembled side-by-side to make an uninterrupted stream of air. The curtain is mounted horizontally or vertically for permanent (on the left/right side of the doorway). The ACR Pro air curtain is advised to be wider (in case of horizontal mounting) or higher (in case of vertical mounting) than the gate way.
  • Page 8 To mount the curtain horizontally in a proper way, keep the dis- tance of min. 300mm from the rear side of the device. To mount the ACR Pro curtain to the ceiling, use the ACR Pro multi-purpose connector. Mounting pins of diameter 11 may be attached to the connector (not included in the delivery).
  • Page 9: Controller Installation

    ACR Comfort is a controller that allows to regulate air speed and desired temperature in the room. ACR Comfort should be located beyond the air stream generated by the air curtain. The ACR Comfort allows to regulate 1 pc of ACR PRO unit. Description of the ACR Comfort settings: ON/OFF –...
  • Page 10 Acr Pro air curtains Operation and Maintenance Documentation Settings menu When Panel Intelligent is switched off, press Setting Option Value and hold MODE for 5 seconds. menu To change option use MODE button. Temperature calibration -9 °C ~ +9 °C To change value use +/- buttons.
  • Page 11: Electrical Connection Diagrams

    ACR Pro curtain starts operating accordingly to the parameters set in the control panel of the device. The Multi 6 control box allows to connect and control up to 6x ACR Pro 2000 and 6x servomotors. The control of the unit motors is via COMFORT or INTELLIGENT controller, there is a possibility to connect DOORSTOP switch to it.
  • Page 12 Acr Pro air curtains Operation and Maintenance Documentation 8.1 Connection scheme for 1 unit ACR Pro H or C type with Comfort controller ACR Pro 8.2 Connection scheme for 1 unit ACR Pro E type with Comfort controller ACR Pro E...
  • Page 13 Acr Pro air curtains Operation and Maintenance Documentation 8.3 Connection scheme for ACR Pro H or C type with custom controller ACR Pro ACR Pro 8.4 Connection scheme for ACR Pro E type with custom controller ACR Pro E ACR Pro E...
  • Page 14 Acr Pro air curtains Operation and Maintenance Documentation 8.5 Connection scheme for 6 unit ACR Pro H or C type with Multi 6 and Comfort...
  • Page 15 Acr Pro air curtains Operation and Maintenance Documentation 8.6 Connection scheme for 6 unit ACR Pro E type with Multi 6 and Comfort...
  • Page 16: Water Connection

    OPERATION AND MAINTENANCE The engine and fan used in the ACR Pro air curtains are maintenance-free devices but regular check-ups are advised, especially mo- tor and bearing (fan’s rotor should rotate freely, free from any axial and radial throws/run-outs and undesired knocks/rattles.
  • Page 17 GUARANTEE AND SERVICES PRESERVE THIS WARRANTY Type: Serial no.: Date of purchasing:: LIMITED GUARANTEE * The manufacturer guarantee the costumer that the product and its parts are free from material and production failures. During normal use the warranty is 2 years. This warranty concerns the first retail customer.
  • Page 20 PAKOLE TRADE Kft. H-8000 Székesfehérvár, Börgöndi út 8-10. www.pakole.com mail@pakole.hu Tel.: +36 22 316 484 Fax.: +36 22 316 074...