Pakole GHI-11 User Manual

Pakole GHI-11 User Manual

Natural or propan -gas working gas infrared ceramic heaters

Advertisement

Quick Links

User's Manual
NATURAL OR PROPAN -GAS WORKING
GAS INFRARED CERAMIC HEATERS
Appliance types:
GHI-7...36
www.pakole.com
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GHI-11 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pakole GHI-11

  • Page 1 User’s Manual NATURAL OR PROPAN -GAS WORKING GAS INFRARED CERAMIC HEATERS Appliance types: GHI-7...36 www.pakole.com...
  • Page 2: Table Of Contents

    Type infrared ceramic heaters Contents Contents 1. Safety information ...............................3 2. General Instruction .............................4 Installer’s responsibilities ...........................4 Data board .................................4 Corrosive materials ............................4 Standards and laws ............................5 Safety signs ...............................5 Safe usage ................................5 3. Transportation, unpacking, handling .......................6 4. Operation principle ..............................6 5.
  • Page 3: Safety Information

    Type infrared ceramic heaters User’s Manual Safety information GENERAL SAFETY NOTICES Disregard of instructions and notices of this Manual can cause serious bodily injuries or damages as follows: burning, explosion, suffocation, carbon monoxide poisoning, electric shock and in ex- treme case death! This appliance can only be used and serviced by such persons who understood and follow the in- structions of this Manual If you need help or information concerning the appliances –...
  • Page 4: General Instruction

    The appliance is equipped with data board, which is placed on outside of device’s door. On this data board there are information con- cerning the type of device, gas type, electrical connection and flue types. Manufacturer Distribute: PAKOLE Trade Kft. PAKOLE Trade Kft. 8000 Székesfehérvár, Börgöndi út 8000 Székesfehérvár, 8-10.
  • Page 5: Standards And Laws

    Qualified service engineers are those having specific technical experience and/or valid license in the field of heating and cooling in- stallation for home and industry. In any case, call the Manufacturer office or the closest dealer (www.pakole.com) and ask for further informations.
  • Page 6: Transportation, Unpacking, Handling

    Type infrared ceramic heaters User’s Manual Transportation, unpacking, handling • The delivery must be made according to the following: → The package must be carefully secured in the loading space. → The package must be transferred in a closed space (always keep packing parts away environmental impacts). •...
  • Page 7: Installation

    Type infrared ceramic heaters User’s Manual Installation Drawings and dimensions of the appliances mounting bracket (This is not the part of the equipment) mixing housing control section Reflector Isolated...
  • Page 8: Assemblage Process Of The Appliances

    65 7 B design 5 82 2.picture: Gas working infrared heaters type diagram Type Design Weight (kg) GHI-7 14,5 One mixing housing GHI-11 One mixing housing GHI-18 1020 One mixing housing GHI-23 Two mixing housing GHI-36 1020 Two mixing housing Assemblage process of the appliances 1. The mounting brackets need to be mounted on the unit with M8-screws.
  • Page 9: Appliance Installation

    Type infrared ceramic heaters User’s Manual Appliance installation • SOLELY INTERIOR installation is possible. • The installation must comply with the valid standards. • For the sake of appropriate effeciency the position and the high of installation has to be carefully defined. •...
  • Page 10: Electrical Connection

    Type infrared ceramic heaters User’s Manual Electrical connection ATTENTION! Both the ignition control needs 230V/50Hz mains voltage. Before connecting the appliance to the gas pipe line, please disconnect it from the power line and close the gas valve front of the burner. The appliance must be connected to a grounded power supply system! If the above instructions are not followed that can lead to death, heavy injuries or property demages! CAUTION...
  • Page 11: Electrical Connection Scheme Of Honeywell S4965R2027

    Type infrared ceramic heaters User’s Manual Electrical connection scheme of HONEYWELL S4965R2027 type automatic burner control VK4125 7. picture: Connection points of S4965R2027 automatic burner control If You followed the above instructions, and the appliance is assembled, installed and electronically connected to the power line, then the following final control is recommended.
  • Page 12: Suspension

    Type infrared ceramic heaters User’s Manual Suspension Warning! DO NOT ALLOWED to install he GHI appliances into “A” and “B” specified fire-protection class! The installation must comply with the valid standards! Disregard of these instructions can result in death, injury or property damage! Infrared heaters are to be mounted on welded or assembled consoles built in the side wall of the hall to be heated, eventually on the ceiling, and secured with M8 bolts.
  • Page 13: Check At The Beginning Of Season

    Type infrared ceramic heaters User’s Manual The first adjustment of the appliance must be carried out only from a well educated technician! To fulfil this requirement the easi- est way if You order this procedure by the producer or by the nearest distributor. If You decide to order the first adjustment procedure by the producer or by the distributor please feel free to contact our colleagues! 11.picture: Assemblage of the gas magnetic valve ATTENTION! At the first start need to check the outlet gas pressure!
  • Page 14: Maintenance Supervisions By The Customer

    Gas change Attention! By disambeling or modiffying the unit please turn to our Service center. (PAKOLE Trade ltd. HUNGARY, 8000, Székesfehérvár, Börgöndi út 8-10. , e-mail: mail@pakole.hu, tel.: +36 22/316-484) Avoiding to do so may result in death, injury or material damage.
  • Page 15: Troubleshooting

    Type infrared ceramic heaters User’s Manual Troubleshooting Malfunctions Symptoms Possible causes Corrective actions Ignition and flame Ceramic Surface sensing system • The electrodes of igniter is polluted • Clean electrodes • Electrical connection between igniter and • Check electrical connection automation is broken between ingnition module and auto There is no spark be-...
  • Page 16: Enclosure

    GHI - 23** 19,7 2,09 1,63 GHI - 36 29,8 3,16 2,46 * At the GHI-11 appliances the net heat input is 10 kW, with propane gas. ** At the GHI-23 appliances the net heat input is 20 kW, with propane gas.
  • Page 17: Enclosure 3.: Target Countries/Gas Categories

    Type infrared ceramic heaters User’s Manual Enclosure 3.: Target countries/gas categories Gas pressure of connection (mbar) Target Appliance Exhaust countries category possibilities 2. family 3. family II2H3B/P II2E+3+, I3P 20/25 30/37, 50 II2H3B/P 30, 50 II2H3+, I3B/P 30/37, 50 II2H3P II2H3B/P 37/50, 37, II2H3+, II2H3P...
  • Page 18: Eco-Design-Declaration Of Conformity

    Permanent pilot flame power requirement Pilot flame pow- er requirement pilot (if applicable) Contact PAKOLE Trade Kft. H-8000 Székesfehérvár, Börgöndi út, 8-10 details (*) NOx= nitrogenoxides. (**) For luminous local spaceheaters the weighted thermal efficiency is by default 85,6 %.
  • Page 19 GHI-11 Ceramic radiant heaters with insulated reflector Model: Type of heating: Ceramic radiant heaters Fuel: Gaseous Type of fuel: Natural Gas Propane Butane Propane-Butane Space heating emmission (*) NO x mg/kWh (GCV) input Characteristics when operating with the preffered fuel only...
  • Page 20 Permanent pilot flame power requirement Pilot flame pow- er requirement pilot (if applicable) Contact PAKOLE Trade Kft. H-8000, Székesfehérvár, Börgöndi út, 8-10 details (*) NOx= nitrogenoxides. (**) For luminous local spaceheaters the weighted thermal efficiency is by default 85,6 %.
  • Page 21 Permanent pilot flame power requirement Pilot flame pow- er requirement pilot (if applicable) Contact PAKOLE Trade Kft. H-8000, Székesfehérvár, Börgöndi út, 8-10 details (*) NOx= nitrogenoxides. (**) For luminous local spaceheaters the weighted thermal efficiency is by default 85,6 %.
  • Page 22 Permanent pilot flame power requirement Pilot flame pow- er requirement pilot (if applicable) Contact PAKOLE Trade Kft. H-8000, Székesfehérvár, Börgöndi út, 8-10 details (*) NOx= nitrogenoxides. (**) For luminous local spaceheaters the weighted thermal efficiency is by default 85,6 %.
  • Page 23 If you would like to contact us the type and serial number of device always be at hand. In case of other needed information write to the following address: PAKOLE TRADE Kft. H-8000 Székesfehérvár, Börgöndi út 8-10. Tel.: +36 22 316 484...
  • Page 24 PAKOLE TRADE Ipari és Kereskedelmi Kft. H-8000 Székesfehérvár, Börgöndi út 8-10. Honlap: http://www.pakole.hu E-mail: mail@pakole.hu Tel.: +36 22 316 484 Fax.: +36 22 316 074...

This manual is also suitable for:

Ghi-7Ghi seriesGhi-18Ghi-23Ghi-36

Table of Contents