Booster B-3

8. Operation

LED
The LED on the front lights or flashes indicating the operation modes or
problems that occur.
LED
constantly lighting
slowly flashing
(apprx. 1 sec. cycle)
quickly flashing
Shunting the boundry between two booster sections
You should take care not to allow locomotives or trains to halt directly
on the boundary between two sections. This would lead to a connection
between the outputs and possible damaging of the two connected
boosters. The short circuit indication does not work under these
circumstances.

9. Check list for troubleshooting

The booster is getting too hot and/or starts to smoke.
Disconnect the system from the mains immediately!
!
Possible reason: The connections to the track and the power supply
have been mixed up. à Alter the connections. Possibly the booster
has been damaged.
The LED at the booster does not light and the locomotives cannot be
driven.
Possible reason: The power supply has been interrupted. à Check
the connections to the power supply (transformer).
Meaning
booster in operation
no signal from the control unit
short circuit at the track output