Casio IT-9000 Series Service Manual page 67

Hide thumbs Also See for IT-9000 Series:
Table of Contents

Advertisement

3.
Cradle I/F (USB-Client)
<Required equipment>
Connect equipment as follow.
Test Object
* Pre-installation of the Microsoft ActiveSync/Windows Mobile Device Center is required.
Depends on OS to be used.
ActiveSync: for Windows XP or earlier,
Windows Mobile Device Center: for Windows Vista or later
<Preparation of you PC>
• Install "LMWIN" before starting test.
• Script fi les
Make fi les referring to the following format and save them to the folder (C:\Program Files\LMWIN)
on your PC.
/SO "C:\USBDATA.DAT" C:\FlasdDisk\DIAG\WLAN
/RO C:\FlashDisk\DIAG\WLAN\USBDATA.DAT C:\
• Store USBDATA.DAT on the C: drive.
<Testing procedure>
No.
Operation
Start up "LMWIN" on your
PC and execute the script fi le
"CradleIF(Client)".
Confi guration of "LMWIN":
USB
1
Start up "CradleUSBTest"
under \\My Device\FlashDisk\
DIAG.
Check the test result and
2
press the "ENT" key.
USB cable
(to connect cradle to PC)
Ethernet cradle
Display
– 60 –
PC*
AC adaptor & AC cord
Test Details
Automatically judges the
test result after transferring
USBDATA.DAT (128 KB)
between the PC and IT-9000.
Test is completed and the
screen returns to the OS
screen.
IT-9000