7.4. Method for Loading/Unloading of Mechanism
CAUTION:
If loading does not start after DC Power Supply is applied, DO NOT
continue to apply DC Power.
Apply +3 VDC Power Supply to the Loading Motor terminals.
Loading:
DC (-) to Portion "a," DC (+) to Portion "b"
Unloading:
DC (+) to Portion "a," DC (-) to Portion "b"
Fig. 5
28