7. Use an adjustable wrench to tighten the threaded end of the kit to 6 to 7 ft lbs.
8. Use an adjustable wrench and tighten the round end of the kit to about 3 ft lbs.
Figure 9 Exploded View of the Sealing Gland Installation
2.1.4 Installing the Ground Cable
Savari recommends proper grounding to prevent damage to the RSU. The grounding point for
the RSU is located on the side. The RSU consists of a ground screw that can be loosened to
attach a ground wire. Damage from static buildup can be prevented with proper grounding.
Savari suggests installing a grounding strap from the antenna ground to a well-designed local
earth ground. It is recommended to use a ground wire that is no more than a few meters and of
suggested AWG 14 or better.
Savari Inc., Confidential
Copyright © Savari, Inc. 2017
StreetWAVE™SW-1000™ Installation Guide