Control panel for rolling shutters up to 1200watt

Advertisement

Functions and connections
goes ON after a while. Keep it pressed until the RED indication light
goes OFF. The memory is now clear.
Adding a new transmitter with the control panel
button:
Press the CODE button and the RED indication light goes ON (after
a small delay). Leave it and during the next 3 seconds, press the
desired transmitter channel button until the RED indication light
blinks and goes OFF. The new transmitter is saved. Follow the same
procedure to program more (up to 300) new transmitters.
Working time:
Adjustable from 1-180S. While the gate is fully closed, press and
keep the TIME button of the control panel pressed until the gate
goes to fully open position. Then leave it. The working time is
saved.
Adding a new transmitter remotely:
The motor is fully closed or open. Press a working transmitter
button (already in memory) to start the motor working and hold it
pressed until the motor stops. When it stops, leave it and press the
new transmitter button immediately. The new transmitter is saved.
Repeat steps to program more transmitters remotely. When the
memory is full (300 transmitters) you cannot add more new
transmitters.
Pedestrian function:
When the pedestrian traverses the gate, the gate will open for a
while and then automatically will close. Photocells need to be
installed. The time of closing is the same with the second time of
A/C.
Photo-cell connection:
Connect the photocell contact and power supply 24VAC according
to the diagram in the right. When you finish, put the program
dipswitch 5 in ON position.
Power
supply
230V:
Supply
the
control
panel
with
230Vac.Check that the
yellow indication light
is ON. Press the button
of the transmitter and
check
the
red
indication light is ON
(receiver).
Photocell operation:
beam is cut-off, the door stops immediately and automatically
Clear memory:
activates the open function. If the photocell beam is cut-off, the
The first step is to clear
door never closes.
the
control
panel
memory.
Press
the
Blinker light function:
button CODE of the
The blinker light gives a permanent voltage of 230V / 10W, connects
control panel and the
to terminals 1 & 3 and operates as long as the gate is moving. If
RED
indication
light
you want to flashes for more time, eg 100 seconds, then program
100-second for the working time of the control panel.
Adjusting the auto close time:
There is a double counter in the A/C function. The first one is 120
seconds and is applied when the door stops after an open function.
During this counting time of 120 sec., if the photocell beam is
disturbed, then after the beam is free, the A/C counting time
becomes 10 sec. until the fully closed position. In this control panel,
the second counting time of 10 sec., can be regulated. Press the
TIME button, keep it pressed and within 1 sec. , press the CODE
button.
seconds of the counter. The time of the counter is from 1-120
seconds. Keep it pressed for the time you wish to give in A/C and
pedestrian function. The dipswitch 3 needs to be ON.
Indication light LED:
There are indication LED lights that displays the different functions
of the control panel for the photocells.
Reset
automation
Case
please
power supply (230Vac)
for
reconnect and recheck.
Compatible
transmitters
Based on the model you
have,
appropriate transmitter.
Proedrou Drakaki 11 ,173 41 Agios Dimitrios
Call center: 210 9850 244, Fax: 210 9823 264
When the door closes and the photocell
The red indicating light starts flashing, indicating the
the
:
of
malfunction,
remove
the
10
seconds,
:
select
the
www.profelmnet.com

Advertisement

loading

This manual is also suitable for:

Psr 3029Ptr 3029Ps-3029Pn-3029