3029
Control panel for rolling shutters up to 1200watt
Code
Frequency
PSR/PTR - 3029
433,92/868,3
PS-3029
433,92
PN-3029
433,92
Check all connections. Check the terminal switches of the motor. The BLUE/GREY (common) motor wire is connected in terminal 4. Earth motor
wire is not connected in the control panel.
Covering distance: from 30 – 100 μ. depends on external
conditions.
TRANSFORMER
12
V - 1,5VA
230V
FLASH
1
2
3
4
5
6
7
M
230VAC
Terminal
Photocell
Codification
Switches
Keeloq
YES
Rolling
Standard
YES
Profelmnet
YES
Rolling
TRANSFORMER
24V - 1,5VA
CODE
ΧΡΟΝΟΣ
PROGRAMMS
ON
1 2 3 4 5 6 7 8
PHOTOCELL
8
9 10 11 12 13 14 15
24VAC
60mA
Ext.Butto
Auto close
s
n
YES
YES
YES
YES
YES
YES
YES
YES
YES
Function description
Νο
Not used
1
Not used
2
AUTO-CLOSE FUNCTION
OFF: No auto close
ON: Auto-close. Embedded auto close function. Works with
the photocell. When the gate opens and there is no access
(no obstacle detection from the photocell), the A/C time is
120 seconds (the gate will close after 120 seconds). If there is
3
access and obstacle detection from the photocell, then the
A/C time is 10 seconds (the A/C timer counts 10 seconds after
the photocell is free and then the gate will automatically
close). The second time of A/C can be changed (follow the
below instructions).
Not used.
4
PHOTOCELLS
OFF: NO photocells.
ON: Photocells. The power supply of the photocell 24VAC in
5
terminals 13&14 and COM & NC of the photocell in terminals
8 & 9.
Not used
6
MOTOR REVERSION
OFF/ON: The first move of the motor needs to be opening,
7
after the power of control panel. When the first move is
closure, switch the dipswitch 7 to the opposite position.
ANTENNA
Not used
8
Proedrou Drakaki 11 ,173 41 Agios Dimitrios
Call center: 210 9850 244, Fax: 210 9823 264
www.profelmnet.com
Light
Motor
Slow
230V
torque
move
YES
NO
NO
YES
NO
NO
YES
NO
NO
Reverse
Memory
move
YES
300
YES
300
YES
300