H3C S12500 Series Configuration Manual
H3C S12500 Series Configuration Manual

H3C S12500 Series Configuration Manual

Hide thumbs Also See for S12500 Series:

Advertisement

Quick Links

H3C S12500 Series Routing Switches
OAA Configuration Guide
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Software version: S12500-CMW730-R7374
Document version: 6W731-20150528

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S12500 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for H3C S12500 Series

  • Page 1 H3C S12500 Series Routing Switches OAA Configuration Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Software version: S12500-CMW730-R7374 Document version: 6W731-20150528...
  • Page 2 Copyright © 2014-2015, Hangzhou H3C Technologies Co., Ltd. and its licensors All rights reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.
  • Page 3 The H3C S12500 documentation set includes 17 configuration guides. These guides describe the software features for the H3C S12500 Series 10G Core Routing Switches and guide you through the software configuration procedures. These guides also provide configuration examples to help you apply software features to different network scenarios.
  • Page 4 Convention Description bars, from which you select one choice, multiple choices, or none. The argument or keyword and argument combination before the ampersand (&) sign can &<1-n> be entered 1 to n times. A line that starts with a pound (#) sign is comments. GUI conventions Convention Description...
  • Page 5 Guides you through installing adjustable slider rails Installation Guide to a rack. H3C High-End Network Describes the hot-swappable modules available for Products Hot-Swappable the H3C high-end network products, their external Module Manual views, and specifications. Describe software features and configuration Configuration guides procedures.
  • Page 6 Obtaining documentation Access the most up-to-date H3C product documentation on the World Wide Web at http://www.h3c.com. Click the links on the top navigation bar to obtain different categories of product documentation: [Technical Support & Documents > Technical Documents]—Provides hardware installation, software...
  • Page 7: Table Of Contents

    Contents Configuring the OAP module ······································································································································ 1   Internal interfaces for OAP modules ······························································································································· 1   Logging in to an OAP module ········································································································································· 2   Logging in through the console port on the OAP module ···················································································· 2   Logging in through the management Ethernet port on the OAP module by using Telnet ································· 3  ...
  • Page 8: Configuring The Oap Module

    Configuring the OAP module H3C Open Application Architecture provides an open interface for third-party vendors to develop and integrate value-added applications into H3C products. These applications can apply to one of the following forms: A standalone network device. • A card that can be installed in a network device (Open Application Platform module, or OAP •...
  • Page 9: Logging In To An Oap Module

    Figure 1 Diagram for the internal interface When using internal interfaces, follow these guidelines and restrictions: For successful traffic forwarding, the two internal interfaces on an LST1IPS2A1 module must be up • at the same time. • You can add the two internal interfaces on an LST1IPS2A1 module to an aggregation group to implement dynamic backup.
  • Page 10: Logging In Through The Management Ethernet Port On The Oap Module By Using Telnet

    Stop bits—1. Flow control—None. Follow the OAP module user guide to log in to the operating system of the OAP module through the terminal emulation program. Logging in through the management Ethernet port on the OAP module by using Telnet You can Telnet to the OAP module through its management Ethernet port by using either of the following methods: •...
  • Page 11: Redirecting To The Oap Module From The Device

    From the switch, establish an SSH connection to the IP address of the OAP module's management Ethernet port. After the SSH connection is successfully established, you are logged in to the operating system of the OAP module. Using SSH to log in to the OAP module from a PC: •...
  • Page 12 Pressing the reset button of the OAP module has the same effect. The device can still identify and control the OAP module after the module starts up again. Perform the following task in user view: Task Command • In standalone mode: oap reboot slot slot-number Reset the OAP module.
  • Page 13: Configuring Oap

    Configuring OAP Overview Open Application Platform (OAP) is an open application protocol for supporting emerging services. It provides a method for information exchange and collaboration between the ACFP server and ACFP client. ACFP is an application control forwarding protocol based on the OAA architecture that uses the client/server model.
  • Page 14: Configuring Oap

    Configuring OAP Enabling OAP Step Command Remarks Enter system view. system-view interface interface-type Enter interface view. interface-number By default, OAP is disabled on an Enable OAP. oap enable interface. Setting the clock synchronization timer Step Command Remarks Enter system view. system-view By default, the clock Set the clock synchronization...
  • Page 15: Shutting Down An Oap Client

    Shutting down an OAP client This feature applies only to OAP clients on Linux. To shut down an OAP client: Step Command Enter system view. system-view Shut down an OAP client. oap client close client-id Displaying and maintaining OAP Execute display commands in any view. Task Command Display the summary registration information...
  • Page 16: Index

    Index OAP module CLI login, OAP module management Ethernet port login, 3, ACFP OAP, OAP function configuration, function OAP manager configuration, OAP client, application control forwarding protocol. See ACFP OAP manager, internal interface OAP module CLI login, OAP module, client OAP client management, logging in OAP client monitoring timer, 6,...
  • Page 17 OAP module management Ethernet port port login, 3, OAP module CLI login, OAP module reset, OAP module management Ethernet port login, 3, network management procedure OAP configuration, displaying OAP, OAP function configuration, enabling OAP, OAP module internal interface, logging in to OAP module (CLI login), logging in to OAP module (console login), logging in to OAP module (management Ethernet port login), 3,...