Champion Power Equipment 100166 Operator's Manual
Champion Power Equipment 100166 Operator's Manual

Champion Power Equipment 100166 Operator's Manual

1 in. (2.5 cm) water pump with hose kit

Advertisement

Quick Links

OPERATOR'S MANUAL
MODEL #100166
1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT
REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.com
or visit championpowerequipment.com
SAVE ThESE iNSTRUcTiONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
EN
3713-M-OP
REV 20220405
Champion Power Equipment, Inc., Santa Fe Springs, CA USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 100166 and is the answer not in the manual?

Questions and answers

Summary of Contents for Champion Power Equipment 100166

  • Page 1 This manual should remain with the product. Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice. 3713-M-OP REV 20220405 Champion Power Equipment, Inc., Santa Fe Springs, CA USA...
  • Page 2: Table Of Contents

    TAbLE Of cONTENTS 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT TAbLE Of cONTENTS Storage ............
  • Page 3: Introduction

    100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT SAfETY DEfiNiTiONS iNTRODUcTiON Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to (CPE) product. CPE designs, builds, and supports all of our possible dangers.
  • Page 4: Important Safety Instructions

    SAfETY iNSTRUcTiONS 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT iMPORTANT SAfETY iNSTRUcTiONS DANGER  The water pump develops powerful force. wARNiNG  DO NOT move the water pump when it is in use. DO NOT use Cancer and Reproductive Harm –...
  • Page 5: Fuel Safety

    SAfETY iNSTRUcTiONS 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT fuel Safety wARNiNG  DANGER Water pumped through this unit shall not be used as drinking  water. GASOLINE AND GASOLINE VAPORS ARE HIGHLY FLAMMABLE AND EXPLOSIVE.
  • Page 6 SAfETY iNSTRUcTiONS 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT When transporting or servicing the water pump: Always check that the fuel valve is in the OFF position and the gasoline tank is empty. Disconnect the spark plug wire.
  • Page 7: Safety And Dataplate Labels

    T o be printed on white substrate. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 8: Controls And Features

    AND fEATURES 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT cONTROLS AND fEATURES Read this operator’s manual before operating your water pump. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.
  • Page 9: Parts Included

    AND fEATURES 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT Parts included Accessories Hose Kit 16.4 ft. x 1 in. (5 meter x 25mm) Intake Hose ....26.2 ft. x 1 in. (8 meter x 25mm) Discharge Hose .
  • Page 10: Assembly

    ASSEMbLY 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT ASSEMbLY cAUTiON  Your water pump requires some assembly. This unit ships from our Hand tighten the nut and handle only. Any excess force, with factory without oil. It must be properly serviced with fuel and oil tools or otherwise, may strip or break the threads on the before operation.
  • Page 11: Add Fuel

    ASSEMbLY 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT 3. Using a funnel, add up to 2.4 fl. oz. (70 ml) of oil (not NOTicE  included) and replace oil fill cap/dipstick. It is recommended to only fill to the base of the oil fill hole. DO NOT OVERFILL.
  • Page 12: Operation

    OPERATiON 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT OPERATiON cAUTiON  Use unleaded gasoline with a minimum octane rating of 87 water Pump Location and an ethanol content of 10% or less by volume. wARNiNG DO NOT light cigarettes or smoke when filling the tank.
  • Page 13: Priming The Pump

    OPERATiON 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT Priming the Pump wARNiNG  DO NOT run the pump dry. Running the pump dry can destroy the pump seals and will void the warranty. If the pump was running while dry, stop the engine and allow it to cool thoroughly before filling the chamber with water.
  • Page 14: Connecting The Outlet Hose

    OPERATiON 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT 4. Prime the pump. (E) See priming the pump section NOTicE  The once connected to the pump, there may be some threading left after hand tightening. This is normal. DO NOT overtighten the pipe joint with any wrench, tool, or otherwise.
  • Page 15: Starting The Engine

    OPERATiON 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT Starting the Engine 7. Pull the starter cord slowly until resistance is felt and then pull rapidly. wARNiNG  8. As engine warms up, move the choke lever to “RUN”.
  • Page 16: Maintenance

    MAiNTENANcE 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT MAiNTENANcE changing the Engine Oil Change oil when the engine is warm. Refer to the oil specification Make certain that the water pump is kept clean and stored to select the proper grade for your operating environment.
  • Page 17: Cleaning The Air Filter

    MAiNTENANcE 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT Maintenance Schedule 4. Make certain the spark plug gap is 0.6 - 0.8 mm (0.024 - 0.031 in.). Follow the service intervals indicated in the following maintenance schedule.
  • Page 18: Storage

    STORAGE 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT STORAGE Winter Storage Protect your water pump parts from freezing. For longer term storage, please follow these guidelines. 1. Apply all storage instructions from previous sections. Engine Storage 2.
  • Page 19: Specifications

    SPEcificATiONS 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT SPEcificATiONS NOTicE  Temperature will affect engine oil and engine performance. water pump Specifications Change the type of engine oil used based on temperature Model ............
  • Page 20: Troubleshooting

    TROUbLEShOOTiNG 100166 - 1 iN. (2.5 cM) wATER PUMP wiTh hOSE kiT TROUbLEShOOTiNG Problem Cause Solution No fuel Add fuel Water pump will not start Faulty spark plug Replace spark plug Fill crankcase to the proper level; place water Low oil level pump on a flat, level surface Water pump will not start;...
  • Page 21 Consequential Damage CPE warrants to the original purchaser that the mechanical and Champion Power Equipment disclaims any obligation to cover electrical components will be free of defects in material and any loss of time, use of this product, freight, or any incidental workmanship for a period of two years (parts and labor) from or consequential claim by anyone from using this product.
  • Page 22 THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) Exhaust and Evaporative emissions regulations.
  • Page 23 EXHAUST AND EVAPORATIVE EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Exhaust and Evaporative Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines).
  • Page 24 You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.