Page 1
CODE 080040-710 PM2.5 Sampler LV-250R OPERATION MANUAL Thank you for purchasing this product. This operation manual describes precautions that are important for preventing accidents as well as the procedures used to handle the product. To ensure safety, read this operation manual and the attached warranty thoroughly before use, and ...
Contents Before Use ······································································································· 1 Safety Precautions ···························································································· 2 Product Overview ······························································································ 5 Features ·········································································································· 5 Names of Parts ································································································· 6 Main Unit ······································································································ 6 Main Unit Interior ···························································································· 7 Control Panel ································································································ 8 Instructions for Use ···························································································· 9 Installation Procedure ····················································································· 9 Wiring Procedure ·························································································...
If you discover any errors or omissions, however, please contact your Sibata representative. The copyright of this operation manual belongs to Sibata Scientific Technology Ltd. The reproduction of all or part of this operation manual without prior written permission from Sibata Scientific Technology Ltd.
Safety Precautions The precautionary information that appears in this operation manual is for ensuring that the product is used safely and for preventing injury to you and other people and damage to equipment. It is all important for ensuring safety and so be sure to read it thoroughly before using the product and observe it during use.
Page 5
When the abnormality is judged to be caused by this product, turn the power switch OFF, disconnect the power plug and contact your Sibata agent. Do not use this product in an abnormal state or allow it to be dismantled for repair by non-service personnel. Doing so might cause malfunction or accidents.
Page 6
The main unit can be used with a single-phase 100 V to 240 V (85 V to 264 V) power source, but the power outlet is only designed for 100 V. Contact your Sibata representative or the vendor if you will be using the equipment at a voltage outside of these specifications.
Product Overview The LV-250R is a PM2.5 sampler. It is capable of mass concentration measurements of particulate matter (PM2.5) using a filter, based on the interim measurement manual designated by the Japanese Ministry of the Environment. With this sampler, airborne particulates in environmental air are sucked in at a constant flow rate via a suction port.
Names of Parts Main Unit (13) (12) (11) (10) (1) Sample air inlet (8) Stand (2) PM10 impactor (9) Main unit grip (3) Rainwater trap (10) Twist fastener (4) Ambient temperature sensor (11) Cord stopper (5) Door (12) Power cord (6) Cooling air intake port (13) Eye bolt (7) Cooling air exhaust port...
Control Panel (10) (1) LOW BATTERY : Battery out caution lamp (2) KEY LOCK : Key lock lamp (3) COM. : COM key. This is used to output data to a PC, etc. (4) MENU/ESCAPE : Menu, escape key (5) UP :...
Instructions for Use Installation Procedure Install this equipment at a flat, stable location. To prevent it from overturning, be sure to fasten it by staking the legs of the stand to the floor. There are four anchor bolt holes in the bottom of the stand, and eight rope fastening holes in the stand support column.
Replace the power outlet with one suited to the applicable voltage. For safety's sake, contact your Sibata representative or the vendor if you will be using the equipment at a voltage other than 100 V. Also, be sure to ground the power supply.
Installing and Cleaning the PM10 Impactor The PM10 impactor can be disassembled as described below. Hold the upper section of the PM10 impactor (the parasol-shaped end) securely. Rotate the lower section of the impactor counterclockwise, and then remove it. Impactor upper section Impactor lower section If the interior is dirty, clean it with a soft cloth or paper, or by using pure water to damp them.
Page 14
Attach the glass rainwater trap to the reassembled PM10 impactor. At this point, check that the packing is attached securely. Packing Rainwater trap Insert the PM10 impactor, with the rainwater trap attached, into the inlet pipe on the top of the main unit. Insert it securely, all the way in. Inlet pipe - 12 -...
Page 15
As shown in the figure, attach the ambient temperature sensor to the right side when facing the main unit. After adjusting the position of the ambient temperature sensor, tighten the wing nut securely to fasten the sensor. Ambient temperature sensor Connect the cable for the ambient temperature sensor to the connector on the back of the main unit.
Removing the Filter holder support and PM2.5 Impactor Open the door on the main unit. Remove the PM2.5 impactor and the filter holder support installed inside. Unfasten the catch clips on the left and right sides of the filter holder support. Lower the lower section of the filter holder support, and remove the filter holder from inside.
Replacing the PM2.5 Impactor To maintain the particle-sizing characteristics at 2.5 μm and 50 % cut by using the PM2.5 impactor, mount the impactor filter (a φ37-mm fiberglass filter) in the impactor well (coarse particle catcher). Then cover the filter surface with a layer of impactor oil to prevent the re-scattering of coarse particles.
Replacing the Filter Holder The filter holder is structured as shown in the figure below. As shown in the figure, position the filter, and then attach the filter clamp. Filter clamp PTFE packing Filter PTFE packing Wiremesh Filter holder lower section When positioning the quartz fiberglass filter, first place PTFE packing on top of the wire mesh, followed by the filter, and then more PTFE packing.
Attaching the Filter holder support and PM2.5 Impactor With the lower section of the filter holder support lowered, insert the PM2.5 impactor all the way into the hole in the upper section of the main unit. Next, attach the upper section of the filter holder support by inserting it into the lower section of the PM2.5 impactor.
Plug Valve Check that the plug valve is positioned vertically (valve open position) as shown in the figure. If it is horizontal, the plug valve will be closed. Plug valve closed Plug valve open Note: Never perform sampling with the plug valve closed. This will cause malfunctions. Airtight Test Airtight tests can be performed by attaching a hose joint (optionally available, item code: 080180-2525) and manual vacuum pump (optionally available, item code: 080870-10)
LCD screen, followed by the main screen (preset flow rate). After this, the LV-250R can be operated. When the key switch is turned right from the ON position, the keys are in a locked state.
How to View the LCD Two types of screens are displayed on the LCD, the main and main menu screens. 1. Main Screen (1) Main item S e t u p (2) Sub item S e t F l o w R a t e 1 6.7 (3) Item details display...
Sampling Method (Basic Operations) This chapter describes the basic operations for running this sampler. For detailed operations, or functions not described in this chapter, see the following chapters. 1. Turn the [POWER] switch key to the S e t u p ON position.
Timer Selection When "5 Select Timer" is selected in the Setup sub-menu, a type of ON timer and OFF timer can be selected. There are three types of ON timers as shown below: Manual, Delay Time and Start Time. This is used to manually operate the pump. Sampling is started when [START/STOP] key is pressed in the main screen display.
Sampling Start Time Setting (ON Timer) When "2 Set ON Time" is selected in the S e t u p Setup menu, the sub-menu shown on the S e t T i m e right is displayed and you can set the D e l a y T i m e 2 S t a r t...
Sampling Stop Time Setting (OFF Timer) When "3 Set OFF Time" is selected in the S e t u p Setup menu, the sub-menu shown on the S e t O F F T i m e R u n T i m e right is displayed and you can set the 2 S t o p...
[3] Total Flow Rate Timer Setting (Total Volume) When "3. Total Time" is selected, the digits S e t u p O F F T i m e of integer part is displayed highlighted as S e t T o t a l V o l u m e shown on the right.
Operation Methods Overview of Screen Display [1] Main Screen (Before Sampling) When the sampler is turned ON, "Setup Set Flow Rate" is initially displayed. The display changes in the order shown in the table below by pressing the [UP] and [DOWN] keys. When the display progresses to "Current Date and Time,"...
Page 29
[2] Main Screen (Standby for Sampling Start) When the ON timer is set, the sampler stands by for start of sampling (standby for pump startup). When the [START/STOP] key is pressed in the main screen display, the pump stands by for startup. Initially, "Waiting Time Remaining" is displayed. The display is switched to "Waiting Set ON Time"...
Before Sampling Main Screen [1] Setup Set Flow Rate (Suction Flow Rate Set Value) This displays the suction flow rate set value. S e t u p S e t F l o w R a t e On the last line, for the actual volume flow rate, "Actual VF"...
Page 31
Main Menu 1 Last Data (Latest Measurement Value) The latest (previous) measurement value is displayed with the Last Data menu. When "1. Last Data" is selected in the main menu, the following sub-menu is displayed. Select the menu in the same way as for the main menu. Press the [MENU/ESCAPE] key several times according to the screen display until the display returns to the main screen.
Page 32
Ambient BP. (Ambient Pressure) When "4 Ambient BP." is selected and the [ENTER] key is pressed, the Ambient BP. menu is displayed. When "MIN.," "MAX.," and "AVG." are respectively selected by the [UP] and [DOWN] keys and the [ENTER] key is pressed, the respective ambient pressure minimum value, maximum value and average value during sampling are displayed.
Page 33
Flow Rate (Suction Flow Rate Warning) When the 5-minute average value of the L a s t D a t a suction flow rate has exceeded ±5 % of F l o w R a t e ▼ W a r n i n g >...
Page 34
3 Setup (Settings) When "3 Setup" is selected in the main menu, the following sub-menu is displayed. Select the menu in the same way as for the main menu. Press the [MENU/ESCAPE] key several times according to the screen display until the display returns to the main screen. Setup Menu Display Display Description...
Page 35
* After setting a new value, if the [MENU/ESCAPE] key is pressed before the [ENTER] key is pressed, the screen will return to the Set ON Time menu without the newly entered value being accepted. Start Time (Start Time Timer Setting) S e t u p T i m e When "2 Start Time"...
Page 36
Stop Time (Stop Time Timer Setting) When "2 Stop Time" is selected and the S e t u p O F F T i m e S e t S t o p T i m e [ENTER] key is pressed, the set value of the sampling stop time is displayed.
Page 37
Setup – Select Timer (Timer Selection) When "5 Select Timer" is selected and the S e t u p [ENTER] key is pressed, the Select Timer S e l e c t T i m e r : D e l a y T i m e menu is displayed as shown on the right.
Page 38
Setup – Set Flow Unit (Flow Rate Unit Setting) When "6 Set Flow Unit" is selected and the [ENTER] key is pressed, the Set Flow Unit menu is displayed. Select the respective menu by the [UP] and [DOWN] keys, and press the [ENTER] key.
Page 39
Setup – Set Fault Stop (Fault Stop Setting) When "7 Set Fault Stop" is selected and the [ENTER] key is pressed, the Set Fault Stop menu is displayed. Select the respective menu by the [UP] and [DOWN] keys, and press the [ENTER] key.
Page 40
1-minute intervals and power may no longer be recovered. * Even in the event of a malfunction or other problem, Sibata shall not provide compensation for any data or records that the user failed to obtain or lost, or for any other direct or indirect damage or losses related to that data.
Page 41
6 Test (Device Check) When "6 Test" is selected in the main menu display, the following Test menu is displayed. Select the menu in the same way as for the main menu. Press the [MENU/ESCAPE] key several times according to the screen display until the display returns to the main screen.
Page 42
Flow Rate (Suction Flow Rate Calibration) (1) Connect a "standard flowmeter" to the LV-250R. (2) When "1 Flow Rate" is selected and the C a l i b r a t i o n S t a n d a r d...
Page 43
Ambient BP. (Ambient Pressure Sensor Calibration) Prepare a standard "ambient pressure C a l i b r a t i o n gauge." A m b i e n t B P . A d j . A m b i e n t B P .
Page 44
When "3 Pressure Drop" is selected and the C a l i b r a t i o n P r e s s u r e D r o p [ENTER] key is pressed, the pressure loss A d j . P r e s .
Sampling Start Stanby Main Screen [1] Waiting Time Remaining (Remaining Time Until Sampling Start) The time until sampling starts after the pump W a i t i n g T i m e R e m a i n i n g started up is displayed.
During Sampling Main Screen [1] Sampling Live Flow Rate (Instantaneous Flow Rate) The instantaneous flow rate of the pump is displayed. On the last line, for the actual volume flow rate, "Actual VF" is displayed, and for the volume flow rate after conversion to the standard state, the standard temperature and "Standard VF"...
Page 47
Main Menu 2 Current Data (Current Value) When "2 Current Data" is selected in the main menu, the following sub-menu is displayed. Select the menu in the same way as for the main menu. Press the [MENU/ESCAPE] key several times according to the screen display until the display returns to the main screen. Current Data Menu Display Display Description...
Page 48
Pressure Drop (Filter Pressure Loss) When "5 Pressure Drop" is selected and the [ENTER] key is pressed, the Pressure Drop menu is displayed. When "MIN.," "MAX.," and "30sec AVG." are respectively selected by the [UP] and [DOWN] keys and the [ENTER] key is pressed, the respective filter pressure loss minimum value, maximum value and 30-second average value since sampling was started are displayed.
Page 49
3 Setup (Settings) When "3 Setup" is selected in the main menu, the following sub-menu is displayed. Select the menu in the same way as for the main menu. Press the [MENU/ESCAPE] key several times according to the screen display until the display returns to the main screen. How each of the screens are viewed is the same as "Setup"...
After Sampling is Stopped F i n i s h e d Sampling is stopped either by the preset timer time being reached or by pressing the P r e s s [ D O W N ] [START/STOP] key. When sampling ends d i s p l a y "...
Page 51
Data Logging The measurement results of data logged in chronological order at 1-minute intervals (total flow rate, average flow rate, fluctuation coefficient, ambient pressure, pressure loss, ambient temperature, generation of warning) can be checked by using the LV-250/40B communications cable ( optionally available ) provided with the software. Note, however, that data logged in chronological order at 1-minute intervals may or may not be logged according to the ON/OFF timer settings.
Power Failure Processing When a power failure occurs while the pump is running by a 100VAC power supply, or the battery voltage drops while the pump is running by the DC power supply, the following processing is executed according to the power supply fault stop setting. The power supply fault stop setting is set to ON by default.
Page 53
● During Sampling Processing When a Power Failure Occurs During Pump Operation by 100VAC Power OFF Timer Selction Power Supply Fault Stop Setting Manual Run Time Stop Time Total Volume After a After a After a recovery from a After a recovery from recovery from power failure, the...
When the Battery Voltage Has Dropped to 21 V or Less During Operation by DC power supply Power Supply OFF Timer Selection Fault Stop Setting Manual Run Time Stop Time Total Volume The power The power The power The power voltage fault is voltage fault is voltage fault is...
1. One year has elapsed since flow rate calibration by the manufacturer. 2. The pump operating time has exceeded 5,000 hours. 3. The packing or rubber parts have become stiff, or cracks have developed. If any other problems arise, contact your Sibata agent. - 53 -...
Troubleshooting Inspect the pump again before submitting it for repair. If this does not solve the problem, contact your Sibata agent. Symptom Reason Remedy No display. BATTERY LOW is blinking. Check the DC power supply battery. The power cord is disconnected Connect the power cord to the main from the main unit.
Options and Consumables Item Code Product Name 080040-7001 Communication cable with software for LV-250/LV-40B PM2.5 sampling filters, 47 mm dia., for mass spectrometry (50 pcs.) 080040-7002 080040-7003 PM2.5 filter holder 080180-2505 PM2.5 impactor filter, 37 mm dia. (100 pcs.) Sampling pipe 1 m Sampling pipe joint 080180-2525 Hose joint...
Sibata guarantees repair of production malfunctions under fixed conditions. However, Sibata does not offer any compensation for loss of or damage to data stored on the product. When asking Sibata for repair or other services, make a backup of any required data.
The sampler body is made almost entirely from metals (aluminum and stainless steel). Inquiries If you have any questions about this product, or if there is any other way in which we can be of assistance, contact your Sibata agent. 19.04.18K (05) - 58 -...
Please fill in this sheet in as much detail as possible. Also, attach this sheet when asking for repair. PM2.5 Sampler LV-250R Trouble Notification Sheet If the sampler malfunctions, make a copy of this sheet, fill it in and contact your Sibata agent. Entry Date (y/m/d): Product Conditions of Use Model: : LV-250R...
Page 62
Note) Shape, dimensions, specifications, and other product information are subject to change without notice in the interest of product improvement to the extent that product functions and applications will not be impaired.
Need help?
Do you have a question about the LV-250R and is the answer not in the manual?
Questions and answers