EAM20196
SOLENOID VALVE SYSTEM
EAM30581
TROUBLESHOOTING
If the solenoid valve will not operate, use the following inspection steps.
TIP
Before troubleshooting, remove the following part(s):
1. Seat
2. Fuel tank
Use 12 V battery in this inspection.
1. Check each couplers and wire con-
nection.
OK
2. Check solenoid valve. (Check sole-
noid valve operation. Solenoid
valve coil)
Refer to "CHECKING THE SOLE-
NOID VALVE OPERATION" on
page 8-10 and "CHECKING THE
SOLENOID VALVE COIL" on page
8-10.
OK
3. Check CDI magneto. (Source coil)
Refer to "CHECKING THE
SOURCE COIL" on page 8-9.
OK
Replace the CDI unit.
SOLENOID VALVE SYSTEM
Reconnect.
NG
Replace the solenoid valve.
NG
Replace the source coil.
NG
8-3