Delta DOP-107H Series Instruction Sheet

Delta DOP-107H Series Instruction Sheet

Advertisement

Available languages
  • EN

Available languages

Quick Links

High color‧Controllable‧User-friendly
DOP-107H
No.18, Xinglong Rd., Taoyuan City
Instruction Sheet
(1) General precautions
Thank you for purchasing this product. This DOP-107H instruction sheet provides information for the DOP-107H series
HMI. Before using this product, read through this instruction sheet carefully to ensure the correct use of the product.
Keep this sheet handy for quick reference whenever needed. Before finishing reading this sheet, follow the following
instructions.
Install the product in an indoor environment which is free of vapor, corrosive and inflammable gas.
Refer to the wiring diagram when connecting the wires.
Ensure this product is correctly grounded. The grounding method must comply with the national standard
guidelines (refer to NFPA 70: National Electrical Code, 2005 Ed.).
Do not change the wiring when power is on.
Do not touch the power supply when power is on, or it may cause electric shock.
When the HMI displays a low power notification and requires a battery change, contact the local distributor or
Delta Customer Service Center for the replacement. Do not change the batteries by yourself.
If you have any inquiry during operation, contact the local distributors or Delta Customer Service Center. The instruction
sheet may be revised without prior notice. Contact our distributors or download the latest version from the Delta website
http://www.deltaww.com
(
).
(2) Safety precautions
Pay attention to the following safety precautions during installation, wiring, operation, maintenance, and inspection.
Installation
 Comply with the instructions specified in the user manual for installation, or it may cause damage to
the equipment.
 Avoid exposing the product to an environment containing vapor, corrosive gas, inflammable gas, or
other foreign matter, or it may cause product damage, electric shock, fire, or explosion.
 Do not install the HMI in an environment where the ambient temperature exceeds the specified
range, or it may cause abnormal operation or product damage.
 This product has the approval of KC Class A (for commercial devices), which is designed for
commercial or industrial use, rather than for domestic use. If you have unintentionally purchased or
sold the HMI products, replace them with products having the approval of KC Class B (for domestic
use).
 Do not install the HMI to the machinery that may cause personnel injury, equipment damage, or
emergency stop.
Wiring
 Connect the ground terminals to class-3 ground system. Ground resistance should not exceed 100Ω.
Improper grounding may cause communication error, electric shock, or fire.
 Do not connect other wire rods to extend the cable length, or it may cause poor communication or
malfunction.
Operation
 Program the HMI screens with the DOPSoft software. If the HMI is not well-programmed, it may
cause abnormal operation. To avoid personnel injury or equipment damage during operation, ensure
the communication error occurring between the HMI and controller or equipment does not cause
malfunction when programming the HMI screens.
 Back up the programmed HMI screens and programs to avoid unexpected data loss.
 Place the HMI on a flat surface or hang it with the hook on its back to prevent it from falling and thus
crashing.
 Do not change the wiring when power is on, or it may cause electric shock or personnel injury.
 Do not touch the panel with sharp objects, or it may make a dent in the panel, resulting abnormal
operation of the HMI.
Maintenance and inspection
 Do not touch the internal parts of the HMI, or it may cause electric shock or product damage.
 Do not touch the wiring terminals within 10 minutes after turning off the power. The residual voltage
may cause electric shock.
Wiring method
 The voltage applied to the HMI should not exceed the specified range, or it may cause product
damage, electric shock, or fire.
 If any cable removal is forced, check the connection again before resuming the operation.
Communication wiring
 Ensure the ground circuit is correct to avoid poor communication.
 To prevent excessive interference from causing abnormal operation of the HMI, place the
communication cable, all power cables, and the motor power cable in separate conduits.
(3) Model explanation
(1)
Product name
(2)
Series
Delta Electronics Inc,
(3)
Panel size
(4)
33068, Taiwan
Display
(5)
resolution
(6)
External device
(7)
Cable length
(8)
Connector
(4) Description of each part
DOP-107HE42x / DOP-107HE46x / DOP-107HS42x / DOP-107HS46x (front view)
DOP-107HE42xZM / DOP-107HE46xZM (front view)
DOP-107HE47xZD (front view)
DOP: Delta Operation Panel (HMI)
1: 100 series HMI
07: 7.0"
HE: Ethernet
Type
HS: standard
4: WVGA
Code
MPG
SD
15 Keys
2
6
7
5: 5 m
A: 10 m
ZM / ZD: D-SUB connector
1
Power indicator
4
Auxiliary keyboard
2
Emergency stop switch
5
Operation / display area
3
MPG
-
-
DOP-107HE42x /DOP-107HE42xZM / DOP-107HE46x / DOP-107HE46xZM / /DOP-107HE47xZD / DOP-107HS42x /
DOP-107HS46x (rear view)
21 Keys
1
3-position operation switch
DOP-107HE42x / DOP-107HE42xZM / DOP-107HE46x / DOP-107HE46xZM / DOP-107HE47xZD / DOP-107HS42x /
DOP-107HS46x (bottom view)
1
USB slave
(5) Installation environment
Before installation, this product must be kept in the shipping carton. In order to retain the warranty coverage and for
maintenance, follow the following instructions for storage. While the product is temporarily not in use:
Store the product in a dust-free and dry place.
Store the product in an ambient temperature of -10°C to +60°C (14°F to 140°F).
Store the product in a relative humidity range of 10% to 90% RH (non-condensing).
Avoid storing the product in an environment containing corrosive gas and liquids.
Properly wrap the product and place it on a shelf or platform.
The suitable installation environment should be a location that is free of devices that generate excessive heat,
water, vapor, dust and oily dust, corrosive and inflammable gas and liquids, airborne dust and metal particles,
vibration, and electronic interference.
This product must be used at an altitude below 2,000 m (6,561.68 feet).
(6) Wiring
D-SUB connector
Pin assignment for DOP-107HE42xZM / DOP-107HE46xZM / DOP-107HE47xZD series (D-SUB)
25-pin D-SUB
1
LAN RD+
2
LAN RD-
3
Reserved
7
Emergency stop – NO(A)
8
Emergency stop – NO(A)
9
Emergency stop – NC(B)
10
Emergency stop – NC(B)
13
0Vdc input (use SELV power supply, isolated from MAINS by double insulation)
14
LAN TD+
15
LAN TD-
18
external power input of MPG
20
output point A of MPG
21
output point B of MPG
22
3-position operation switch – NO(A)
23
3-position operation switch – NO(A)
25
24Vdc input (use SELV power supply, isolated from MAINS by double insulation)
2
Bus
2
SD card
Function

Advertisement

loading

Summary of Contents for Delta DOP-107H Series

  • Page 1 Delta Customer Service Center for the replacement. Do not change the batteries by yourself. If you have any inquiry during operation, contact the local distributors or Delta Customer Service Center. The instruction sheet may be revised without prior notice. Contact our distributors or download the latest version from the Delta website http://www.deltaww.com...
  • Page 2 256 Mbytes 5. Isolated power supply unit is suggested. 6. You can download the DOP-107H series programming software DOPSoft, user manual, and HMI installation sheet 256 Mbytes from Delta’s website. The instruction sheet may be revised without prior notice. Download the latest version from the Delta website (http://www.deltaww.com).
  • Page 3 DOP-107HE42x / DOP-107HE46x / DOP-107HS42x / DOP-107HS46x / DOP-107HE42xZM / DOP-107HE46xZM / /DOP-107HE47xZD (Arka Gö rü nü m) (3) Ürün Açıklaması Ürün Adı DOP: Delta Operatör Paneli (HMI) Yüksek Renk ‧ Geniş Ekran ‧ Kullanıcı Serisi 1: 100 serisi Operatör Paneli...
  • Page 4 2. İzoleli güç devresi dayanma voltajı 1 dakika için 1500 V pik. içerisine girmesini engellemek için önlemler alın. 3. Bazı modeller için sertifika başvuru aşamasındadır. Sertifikalı modeller için Delta Türkiye ile iletişime geçin.  İletişim kablolarının doğru bağlandığından emin olun aksi takdirde anormal 14085.5 ile uyumlu...
  • Page 5 (3) 型號說明 DOP-107HE42x /DOP-107HE42xZM / DOP-107HE46x / DOP-107HE46xZM / /DOP-107HE47xZD / DOP-107HS42x / DOP-107HS46x (背面) 產品名稱 DOP: Delta Operation Panel (HMI) 系列名 1:100 系列人機 高彩‧可控制‧友善人機介面 尺寸 DOP-107H 07: 7.0" Delta Electronics Inc, HE: Ethernet 型別(Type) No.18, Xinglong Rd., Taoyuan City...
  • Page 6 DOP-107HS42x / DOP-107HS46x 尾端出線型式 (7) 基本檢測 DOP-107HS42x DOP-107HE42xZM DOP-107HE42x 型號 DOP-107HE47xZD DOP-107HS46x DOP-107HE46xZM 檢測項目 檢測內容 DOP-107HE46x 定期檢查人機介面與設備連接處的螺絲是否鬆動。  一般檢測 A 接點*1 人機介面若設置於含有害氣體或多粉塵的場所,應防止有害氣體與粉塵的侵入。  額定電壓:< DC 30V 通訊配線應正確,否則可能發生異常動作。  最大額定電流:700 mA 操作前檢測 檢查螺絲或金屬片等導電性物體、可燃性物體是否存在人機介面內。  最小適用負載:DC 3V / 5 mA 人機介面附近使用的電子儀器受到電磁干擾時,請使用儀器調校以降低電磁干擾。 三段式操作按鈕 ...
  • Page 7 (3) 型号说明 DOP-107HE42x /DOP-107HE42xZM / DOP-107HE46x / DOP-107HE46xZM / /DOP-107HE47xZD / DOP-107HS42x / DOP-107HS46x (背面) 产品名称 DOP: Delta Operation Panel (HMI) 系列名 1:100 系列人机 高彩‧可控制‧友善人机界面 尺寸 07: 7.0" DOP-107H Delta Electronics Inc, HE: Ethernet 型别(Type) No.18, Xinglong Rd., Taoyuan City HS: standard 显示规格...
  • Page 8 (7) 基本检测 DOP-107HS42x DOP-107HE42x DOP-107HE42xZM DOP-107HS42x / DOP-107HS46x 尾端出线型式 型号 DOP-107HE47xZD DOP-107HE46x DOP-107HS46x DOP-107HE46xZM 检测项目 检测内容 定期检查人机界面与设备连接处的螺丝是否松动。  一般检测 A 接点*1 人机界面若设置于含有害气体或多粉尘的场所,应防止有害气体与粉尘的侵入。  额定电压:< DC 30V 通讯配线应正确,否则可能发生异常动作。  最大额定电流:700 mA 操作前检测 检查螺丝或金属片等导电性物体、可燃性物体是否存在人机界面内。  最小适用负载:DC 3V / 5 mA (未供应控制电源) 人机界面附近使用的电子仪器受到电磁干扰时,请使用仪器调校以降低电磁干扰。 三段式操作按钮...