Delta R3E Installation Manual

Power monitor

Advertisement

Quick Links

The power behind competitiveness
Delta Power Monitor
Installation Manual
R3E
(for commercial use only.)
www.deltaww.com

Advertisement

Table of Contents
loading

Summary of Contents for Delta R3E

  • Page 1 The power behind competitiveness Delta Power Monitor Installation Manual (for commercial use only.) www.deltaww.com...
  • Page 2: Table Of Contents

    Contents ■Introduction■   Precautions for Your Safety   Essential Points for Safety   Precautions for Use 1.Preparation before construction   1.1Scope of Delivery   1.2Dimension   1.3Descriptions and Functions of Parts and Components 2.Installation   2.1Installation order   2.2System Diagram 3.Setting  ...
  • Page 3: Introduction

    Notations for safe use of the product and their meanings This Installation Manual provides precautions with the following notations and symbols for safe use of the Power Monitor (for commercial use only.) : R3E. Precautions described herein contain important aspects of safety.
  • Page 4 Introduction Warning Do not allow any fire producing objects to be near the Product, or apply any spray, including combustible gases, to the Product. The Product may ignite or explode in the unlikely event such an occurrence takes place. Do not touch the Product with wet hands. Power Monitor may cause injury due to electric shock or equipment malfunction may occur in the unlikely event such an occurrence takes place.
  • Page 5: Essential Points For Safety

    3. Do not install the Product in any place that is prevented from having air flow, such as inside closets or under stairs. 4. Install the Product with the “DELTA” logo facing up when installing the Power Monitor on a wall. When not installed on a wall, set the Product on the Wall Surface/Desktop Mounting Plate when using the Product.
  • Page 6: Precautions For Use

    Introduction Precautions for Use 1. The Product is not a specified measuring instrument that passed any certification criteria of any designated accreditation organization as prescribed by the Measurement Act. The Product may only be used to provide a rough indication on the amount of power. 2.
  • Page 7 Introduction 6. Do not install the product in the following places: ・ Do not expose to extreme fluctuation temperature. ・ Do not expose to salt air. ・ Do not expose to corrosive substances, explosive / flammable GAS, chemicals. ・ Do not install in direct sunlight. ・...
  • Page 8: Preparation Before Construction 1.1Scope Of Delivery

    Preparation before construction 1.Preparation before construction 1.1.Scope of Delivery Verify that following items are available for use prior to using this feature. ■ R3E Product name Shape Remarks Power Monitor 1 unit This is a plate used to install Wall Surface /...
  • Page 9: Dimension

    Preparation before construction 1.2.Dimension ■ 7-inch Power Monitor 32mm 190mm POWER MONITOR ■ Wall Surface / Desktop Mounting Plate 58mm 25mm 40mm 35mm...
  • Page 10: Descriptions And Functions Of Parts And Components

    Preparation before construction 1.3.Descriptions and Functions of Parts and Components Important Do not connect a telephone line to the LAN terminal. ■ Power Monitor ⑧ Front Back Side ① ④ USB 1 ⑩ ② USB 2 CAN-L CAN-H RS485-B RS485-A +12V ③...
  • Page 11: Installation

    Installation 2.Installation 2.1.Installation order 「1. Setting」 「2. Default Settings」 「3. Installation Method」 One Point ・Please set connection ID before connect to the Inverters.  The ID of inverters must be different. ・The ID range is 1~32.
  • Page 12: System Diagram

    Installation 2.2.System Diagram ■ Connection example There are different power distribution methods and connected positions between each inverter model, please check the inverter Operation and Installation Manuals. PV Panel + − + − + − + − Inverter Inverter 2 Inverter 3 Communication Communication connector...
  • Page 13: Setting

    Setting 3.Setting 3.1.Setting the Communications Unit ■Cables   ・ Make sure to use RS-485 cables. Prepare 0.3 to 0.5mm x single wire, 4 cores (twin wires rather than 2 pair) shielded cables (rated temperature: 80ºC to 85ºC).   ・ Read the inverter Operation and Installation Manuals while working.  ...
  • Page 14 Setting ■ Using 2 or more inverters (1) Remove the communications connectors from the inverter, and thread the cables through the waterproof gasket. (2) Hold down the top of the terminal block on the communications connectors, and insert the cables connected to the Power Monitor as follows: 3 DATA+, 4 Data-. (3) Next, insert the cables into the adjacent inverter as follows: 5 Data+, 6 Data-.
  • Page 15: Setting Power Monitor And Cable

    Setting 3.2.Setting Power Monitor and Cable   ・ Process the cables before use. Φ0.6~0.8 Φ5~6 Cable 40mm   ・ Creating 6-pin connectors   Hold down the enclosed 6-pin connector ①, and insert the cable. ①    When the connectors are complete, connect to the main unit.  ...
  • Page 16: Default Settings 4.1Connection

    Default Settings 4.Default Settings 4.1.Connection   (1) After started up, please choose language. Language selection screen   (2) When monitor shows connection is started, please click [YES]. connection setting start screen 接続設定開始画面   (3) When monitor shows time setting, please set up time. Time settings screen (Date and time shown are examples.)
  • Page 17 Default Settings Select the date frame. The date selection screen will be displayed. Select the date that you want to set. Touch the time frame for the time. The time selection screen will be displayed. Select the time that you want to set. 日付選択画面...
  • Page 18 Default Settings   (4) When time setting is done, monitor will show connection set up page.    Please select inverter ID and click [Save]. 接続設定画面 connection setting screen   (5) When ID selection is done, the reconfirm screen will be displayed.    If change is needed, please click [Reconfigure].
  • Page 19: Installation Method

    Installation Method 5.Installation Method The Power Monitor may be mounted on a desktop or on a wall surface for use. “Wall Installation”, “Desktop Installation” and “Wiring access” are respectively explained in this chapter. * Consult the retailer where you purchased the Power Monitor when relocating your Power Monitor. 5.1.Wall Installation ■...
  • Page 20: Desktop Installation

    Installation Method 5.2.Desktop Installation A ② ① ● Desktop installation method  ① Insert the Wall Surface / Desktop Mounting Plate in the insertion slot for anchoring the Desktop Mounting Plate at the lower section of the main unit, being careful about the direction the plate is facing.
  • Page 21: Description Of The Screen Display

    Description of the screen display 6.Description of the screen display 6.1.Home Screen This is the Home screen of the monitor. Illustrations and icons displayed on this screen are explained. ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ① Date / Time The current date and time are displayed.
  • Page 22 Description of the screen display ④ Error icon   An error icon is displayed to indicate that one or more errors are occurring.   The Error icon is ordinarily not displayed, and is displayed when one or more errors occur.   Refer to “8.When Something Seems Wrong (Troubleshooting)” (Page 40) for details. ⑤...
  • Page 23 Description of the screen display ● Display of tabs  The selected tab is displayed in white. The non-displaying tabs are displayed in light blue. Selected tab Non-displaying tab One Point ・ Numerical values that are displayed on the screens are all displayed as values that have been rounded up or off.
  • Page 24: Operation Screens

    Description of the screen display 6.2.Operation Screens The display screen of the Power Monitor changes in the following manner, according to touch panel operations and connection setting. Display details and operations of respective screen are described in the “Display Functions” section. One Point ・...
  • Page 25: Reset Method

    Description of the screen display 6.3.Reset Method ■ Resetting the Power Monitor     Insert an electrically-isolated rod-shaped object with a slender tip into the reset hole on the base     of the unit to push the reset button.     The device will be reset.     ※...
  • Page 26: Service Mode

    Service Mode 7.Service Mode 7.1.Entering or Exiting Service Mode Service mode is a hidden mode for installer. Please do not tell any customer the procedure of entering service mode. Touch the home screen in the following order to enter service mode. Procedure: Touch top left once→Touch top right twice→Touch top left once (Make sure to complete the operation within 5s.) ※...
  • Page 27: Exclusive Service Mode Functions

    Service Mode 7.2.Exclusive Service Mode Functions Service mode provides setting functions such as inverter connection, grid values, time, maintenance, etc. ■ Connection setting   Use service mode to make the connection setting.   ※ During initial monitor startup, the connection setting screen is displayed automatically, but from the second time onwards, it is necessary to switch to service mode to make the connection setting.
  • Page 28 Service Mode   (3) Check the connection status and connection log page under "Inverter status" and "Information".   (4) When the settings are complete, return to normal mode using "Exiting service mode" (page 26).   [Replacing the inverters]   Make the settings as described below if replacing a malfunctioning inverter.  ...
  • Page 29 Service Mode ■ Grid Setting ⑥ ① ② ③ ④ ⑤ ①Use service mode to set grid values.  For the details of grid values, see the inverter Operation and Installation Manual.  The grid setting page cannot be set in normal mode. ②...
  • Page 30 Service Mode ■ Time (1)Select the date frame. The date selection screen will be displayed. Select the date that you want to set. (2)Touch the time frame for the time. The time selection screen will be displayed. Select the time that you want to set. Date selection screen Time selection screen (3)Touch the...
  • Page 31 Service Mode (4)The time change dialog box will disappear, and the time change confirmation dialog box will be displayed. Touch the [Yes] button once again. Time change confirmation dialog box ■ Time (Time Synchronous) Enable:Click to enable time synchronization Server:Fill in sever IP or URL which is going to perform time synchronization Time Zone:Choose time zone Period:Choose interval between each time synchronization Operating method...
  • Page 32 Service Mode ■ Screen setting Screen setting can be set both in service mode and normal mode. ① ② ③ ④ ⑤ ⑥ ① Sleep Mode  The duration of time with no operation until the liquid crystal display on the monitor is  ...
  • Page 33 Service Mode ⑥  A change is confirmed.  * None of the settings will change until the [Save] button is touched at the end. Caution is required.  Touch to turn off the dialog box. Screen Change dialog box Operating method ・Touch and then on the home screen.
  • Page 34 Service Mode ■Other Devices Pyrheliometer/Thermometer can be set on this page. (1)Touch and choose DEA485 to enable pyrheliometer/thermometer. (2)ID range is 41~50. (3)Touch to set, and touch to close dialog.
  • Page 35 Service Mode ・Connection example Communications Connector Pyrheliometer thermometer Power Monitor 6 pin Connector Terminal Modbus Sensor RS-485 Please read the manual of devices before setting, and ask manufacturer if any question.
  • Page 36 ■ Maintenance You can back up and restore data to the Power Monitor. Not displayed in normal mode. For maintenance by Delta. For maintenance by Delta. You can back up the data of the Power Monitor to USB. Restores the backup data from USB to the Power Monitor.
  • Page 37 Service Mode ■ Communication   Communication page is unnecessary to set. It is used to connect other devices by Ethernet. are protocols for other industry to use. Internet setting for the Power Monitor. Need some knowledge of network management to setting.
  • Page 38 The supplementary domain name when a suitable domain name is specified. ⑦ Host Name You can assign a suitable Power Monitor name. The default value is DELTA. No particular settings are required. ⑧ Touch the button to save setting and display the dialog box, and then touch the button.
  • Page 39 Service Mode ■ Power Suppression ② ① ③ ④ ① Date   Year: Year is displayed according to the Gregorian calendar. The year can be changed with a touch.   Month: Month is displayed. The month can be changed with a touch.  ...
  • Page 40: When Something Seems Wrong (Troubleshooting)

    When Something Seems Wrong (Troubleshooting) 8.When Something Seems Wrong (Troubleshooting) 8.1.Error Displays ■ Icons are displayed on the Home screen when an error, malfunction or suppression occurs. ③ ② ① ① Communication Malfunction icon   This icon is displayed when the communication with the Inverter is not available. Icon Operating mode Description...
  • Page 41 When Something Seems Wrong (Troubleshooting) ③ Suppression icon  Displayed when the Inverter is being suppressed. Icon Operating mode Description Temperature elevation The internal temperature of the Inverter has reached a high suppression level. The output of the Inverter is being suppressed. The voltage of the commercial power system has reached Voltage elevation a high level while the Inverter was in operation.
  • Page 42: Troubleshooting

    When Something Seems Wrong (Troubleshooting) 8.2.Troubleshooting ■ Responsive actions that should be taken in cases where the following symptoms occur are described. Symptom Verification details Responsive action Touching the screen will trigger the display of the screen. Nothing is displayed on Is the backlight turned off? The duration of time the screen remains turned on the screen.
  • Page 43: Specifications

    Specifications 9.Specifications 9.1. Power Monitor 32mm 190mm POWER MONITOR Model Screen 7-inch TFT liquid crystal display, 800 x 480 pixels, resistive touch panel. Display color 24-bit RGB (16,770,000 colors) Power generation, calendar history, Inverter information, error log, Displayed details De-rating Log display and the like. Data communication RS-485 method...
  • Page 48 20170113...

Table of Contents