SJFS810VWH
4. Defect display
No.
Status
No defects None None -- --
1
F-thermistor system defect
2
R-thermistor system defect
3
DEF-thermistor system defect
4
Outside temperature-thermistor
system defect
5
ICE-thermistor system defect
6
Defrost defect
7
Cooling fan motor system defect
8
R room fan motor system defect
9
Plasmacluster system defect
10 Operation PWB communication defect
11 Touch IC communication defect
12
Auto ICE Maker system defect
13
Ice storage box is full
14
Water tank is out of water
15
F-thermistor system defect history
16
R-thermistor system defect history
17
DEF-thermistor system defect history
18
Outside temperature-thermistor system
defect history
19
ICE-thermistor system defect history
20
Cooling fan motor system defect history
21
R room fan motor system defect history
22
Plasmacluster system defect history
23
ICE cooling insufficient history
24
F-room high temperature history
25
R-room high temperature history
Buzzer :
= 0.5sec. ON/ 0.5sec. OFF,
LED
Buzzer
Display
None
-- --
E.01
Defect of each thermistor, short circuit/wire breakage of
thermistor wiring and defect of main PWB
E.02
E.03
E.04
Defect of operation PWB.
Defect of each thermistor, short circuit/wire breakage of
E.05
thermistor wiring and defect of main PWB
E.07
Wire breakage of Thermo. fuse, def. heater, defect of main
PWB
(120-minute defrosting has been occurred continuously 2
times within the past 48 hours.)
Defect of wiring / main PWB
E.08
(When fan motor is ON, over current or no current is
E.10
detected.)
E.11
Defect of wiring / main PWB
(When Plasmacluster is ON, over current or no current is
detected.)
E.12
Defect of wiring , Operation or main PWB
(Communication with Operation PWB has been abnormal
over 5 times within the past 48 hours.)
E.13
Defect of touch sheet conector, Operation PWB
(Communication with Touch PWB has been abnormal over
2 times with in the past 48 hours)
E.15
Defect of wiring , ICE Maker , main PWB
None
C.51
(It is not defect)
C.52
(It is not defect)
None
H.61
Defect of thermistor system has been occurred over 1
minute continuously within the past 48 hours
H.62
H.63
H.64
H.65
H.67
Defect of fan motor has been occurred over 3 times
continuously within the past 48 hours
H.68
H.73
Defect of Plasmacluster system has been occurred over 3
times continuously within the past 48 hours.
H.74
Temperature of ICE-thermistor has been reached over
-6°C continuously for 6 hours or more within the past
48 hours.
H.75
Temperature of F-thermistor has been reached over -10°C
continuously for 6 hours or more within the past 48 hours.
H.76
Temperature of R-thermistor has been reached over +10°C
continuously for 6 hours or more within the past 48 hours
= 2sec. ON/ 0.5sec. OFF
20
Content
Correspondance
method
→ [1]
→ [2]
→ [3]
→ [4]
→ [5]
→ [6]
→ [7]
→ [8]
→ [9]
→ [10]
→ [11]
→ [12]
→ [13]
→ [14]
→ [1]
→ [2]
→ [3]
→ [4]
→ [5]
→ [7]
→ [8]
→ [9]
→ [5]
→ [1]
→ [2]

Advertisement