  • Page 1 All manuals and user guides at all-guides.com...
  • Page 2: Safety Warnings

    All manuals and user guides at all-guides.com 1 Safety Warnings Please read this manual carefully before using the iCleaner-120. Before performing maintenance or service on the iCleaner-120 please ensure the power is disconnected to avoid personal injury or property loss. The iCleaner-120 is designed for use in swimming pools only.
  • Page 3: Product Overview

    All manuals and user guides at all-guides.com 2 Product Overview 2.1 Functions ◇ Automatic cleaning: the default mode is automatic, however, this can be overridden using the Remote Control. When the Remote Control is not being used, the iCleaner-120 will return to automatic mode.
  • Page 4 All manuals and user guides at all-guides.com Floating Cable 2.3 Parts List Hook Main Body Parts Guide Vane Drive Belt water retaining board Base Plate Filter Net Base Plate Latch Support Frame Filter Bag (Pic.2.3.2) - 3 -...
  • Page 5 All manuals and user guides at all-guides.com ※ Power Box Parts - 4 -...
  • Page 6: Packing List

    All manuals and user guides at all-guides.com 3 Packing List Serial Quantity Remarks Part Name Number Unit Body Power Box Remote Control Battery Host Guide Vane User Manual Warranty Card Certificate of Quality Synchronous Belt Impeller Spare Parts Filter Bag (Pic.3.2.1)...
  • Page 7: Product Operation

    All manuals and user guides at all-guides.com 4 Product Operation 4.1 Power Connection ※ Please connect the Floating Cable to the Cable Socket of Power Box (see Pic. 4.1.1), then connect the Power Box to an outside AC power of 100v/240v 50/60Hz (see Pic.4.1.2).
  • Page 8 All manuals and user guides at all-guides.com 4.2 Start Up Procedure (1) When placing the iCleaner-120 in the pool: you must wobble the iCleaner-120 according Pic.4.2.1 to make sure the air inside is released when you put the iCleaner-120 in the water, So it will automatically sink to the bottom of pool.
  • Page 9 All manuals and user guides at all-guides.com 4.3 Proper Shut Down and Care (1) To Shut Down The iCleaner-120: Turn the power switch on the power Box to the off position, once the iCleaner-120 finishes working, pull the Floating Cable slowly until the Handle emerges from the water (Pic.4.3.1), and then pull the iCleaner-120 out of the pool by its Handle.
  • Page 10 All manuals and user guides at all-guides.com (3) iCleaner-120 Storage: When the iCleaner-120 is dry,disconnect the floating cable reel it in hand-over-hand and place on the iCleaner-120, then store the iCleaner-120 in a dry,well-ventilated area. If you have the Caddy , please put the iCleaner-120 &...
  • Page 11: Maintenance

    All manuals and user guides at all-guides.com 5 Maintenance 5.1 Impeller ※ Change the Impeller if the old one gets worn or damage Step 1: ※ Rotate Guide Vane clockwise to remove from the iCleaner-120.(Pic.5.1.1) Step 2 ※Use a Phillips head screw driver to remove the bolt in the Impeller according the diagram.(Pic.5.1.2)
  • Page 12 All manuals and user guides at all-guides.com 5.2 Sponge Wheel and Synchronous Belt Replace the Sponge Wheels and Synchronous Belt if they are badly worn or broken Step 1 OPEN ※Invert the iCleaner-120 on the floor, remove the Base OPEN Plate.(Push latch to unlock the Base Plate).(Pic.5.2.1) Step 2...
  • Page 13 All manuals and user guides at all-guides.com Step 3 ※ Using a Phillips head screwdriver and 7mm ring spannerundo the six bolts and nuts on the Side Cover,to remove the Side Cover .( Pic.5.2.3) (Pic.5.2.3) 7 Sponge Wheel Shaft Sleeve 8 Drive Wheel Shaft Sleeve 9 Drive Belt Step 4...
  • Page 14 All manuals and user guides at all-guides.com 1 Drive Wheel Baffle Plate 2 Drive Wheel 3 Synchronous Belt (Pic.5.2.5) Step 5 ※Remove the Drive Wheel and Drive Wheel Baffle Plate, remove the Synchronous Belt (Pic.5.2.5). (Pic.5.2.6) Step 6 ※ Remove the Rolling Brush; Slide the old sponge wheels off, and replace with new sponge wheels(Pic.5.2.6).
  • Page 15 All manuals and user guides at all-guides.com Outside Inside Inside wheel axle Inside Outside (Pic.5.2.7) Step 7 ※Assemble the Rolling Brush to the axle and put the new Synchronous Belt to the Drive Wheel & Roller Wheel (Pic.5.2.7) to aeeemble the Synchronous Belt. (Pic.5.2.9) (Pic.5.2.8) Step 8...
  • Page 16 All manuals and user guides at all-guides.com 7 Roller Wheel Sleeve 8 Drive Wheel Sleeve (Pic.5.2.11) (Pic.5.2.10) Step 10 Step 11 ※Put the Drive Wheel Sleeve and ※ Put the Side Covers to Host Roller Wheel Sleeve to Side and fasten it with bolts & nuts. Covers.
  • Page 17 All manuals and user guides at all-guides.com 5.3 Water Retaining Board Replace the Water Retaining Board if they are broken(Pic 5.3.1) hole Step 1 ※ Remove the base plate from the iCleaner and remove the filter bag, then open the water retaining board to the vertical position and carefully slide the water retainining board to one end, remove the water retainining board...
  • Page 18 All manuals and user guides at all-guides.com 6 Troubleshooting and Warning Lights Commonfault Reason Solution Remarks The socket is Plug in the power lead not plugged in iCleaner-120 doesn't work Connection is wrong Check the connection Impeller is clean the Impeller jammed or dirty Weak pumping Impeller is damage...
  • Page 19 All manuals and user guides at all-guides.com Indicator Indicator Solution Solution Failure Failure light light 1.Check whether the impeller is damaged; The iCleaner Green light Green light 2.Check whether the water pump motor is working; has stopped Water Return the robot to deeper water and restart flashing flashing 3.Put the robot in the water.

Table of Contents