Advertisement

120

Advertisement

Table of Contents
loading

Summary of Contents for ICHRoboter iCleaner-120

  • Page 2 The iCleaner-120 is designed for use in swimming pools only. Any other use is prohibited and will void manufacturers' warranty. Do not swim in the pool whilst the iCleaner-120 is in use in order to avoid personal injury. Do not allow the Power Box to come in contact with water, and it is recommended to be placed in a shady, dry and ventilated area.
  • Page 3 Remote Control. When the Remote Control is not being used, the iCleaner-120 will return to automatic mode. ◇ Overall cleaning: the iCleaner-120 not only cleans the floor of your pool, it also cleans the wall, at the same time, the iCleaner-120 will filter water, and the dirt will be collected into Filter Bag.
  • Page 4 Floating Cable 2.3 Parts List Hook Main Body Parts Guide Vane Drive Belt water retaining board Base Plate Filter Net Base Plate Latch Support Frame Filter Bag (Pic.2.3.2) - 3 -...
  • Page 5 ※ Power Box Parts - 4 -...
  • Page 6 3 Packing List Serial Quantity Remarks Part Name Number Unit Body Power Box Remote Control Battery Host Guide Vane User Manual Warranty Card Certificate of Quality Synchronous Belt Impeller Spare Parts Filter Bag (Pic.3.2.1) - 5 -...
  • Page 7 4 Product Operation 4.1 Power Connection ※ Please connect the Floating Cable to the Cable Socket of Power Box (see Pic. 4.1.1), then connect the Power Box to an outside AC power of 100v/240v 50/60Hz (see Pic.4.1.2). For the complete connection guide please refer Pic.4.1.3 Notices: Do not allow the Power Box to come in contact with water.
  • Page 8 4.2 Start Up Procedure (1) When placing the iCleaner-120 in the pool: you must wobble the iCleaner-120 according Pic.4.2.1 to make sure the air inside is released when you put the iCleaner-120 in the water, So it will automatically sink to the bottom of pool.
  • Page 9 Latch on the Base Plate (Pic4.3.2) and remove the Filter Bag from Base Plate, clean the Filter Bag (Pic.4.3.3), once clean place the Filter Bag on its frame, reassemble the Base Plate and put it back into the iCleaner-120 once the Filter Bag is dry.
  • Page 10 (3) iCleaner-120 Storage: When the iCleaner-120 is dry,disconnect the floating cable reel it in hand-over-hand and place on the iCleaner-120, then store the iCleaner-120 in a dry,well-ventilated area. If you have the Caddy , please put the iCleaner-120 & Floating Cable on to the Caddy Cart, details please refer Pic.4.3.4...
  • Page 11 ※ Change the Impeller if the old one gets worn or damage Step 1: ※ Rotate Guide Vane clockwise to remove from the iCleaner-120.(Pic.5.1.1) Step 2 ※Use a Phillips head screw driver to remove the bolt in the Impeller according the diagram.(Pic.5.1.2)
  • Page 12 5.2 Sponge Wheel and Synchronous Belt Replace the Sponge Wheels and Synchronous Belt if they are badly worn or broken Step 1 OPEN ※Invert the iCleaner-120 on the floor, remove the Base OPEN Plate.(Push latch to unlock the Base Plate).(Pic.5.2.1) Step 2 ※...
  • Page 13 Step 3 ※ Using a Phillips head screwdriver and 7mm ring spannerundo the six bolts and nuts on the Side Cover,to remove the Side Cover .( Pic.5.2.3) (Pic.5.2.3) 7 Sponge Wheel Shaft Sleeve 8 Drive Wheel Shaft Sleeve 9 Drive Belt Step 4 ※...
  • Page 14 1 Drive Wheel Baffle Plate 2 Drive Wheel 3 Synchronous Belt (Pic.5.2.5) Step 5 ※Remove the Drive Wheel and Drive Wheel Baffle Plate, remove the Synchronous Belt (Pic.5.2.5). (Pic.5.2.6) Step 6 ※ Remove the Rolling Brush; Slide the old sponge wheels off, and replace with new sponge wheels(Pic.5.2.6).
  • Page 15 Outside Inside Inside wheel axle Inside Outside (Pic.5.2.7) Step 7 ※Assemble the Rolling Brush to the axle and put the new Synchronous Belt to the Drive Wheel & Roller Wheel (Pic.5.2.7) to aeeemble the Synchronous Belt. (Pic.5.2.9) (Pic.5.2.8) Step 8 Step 9 ※Assemble the Drive Belt on the ※Assemble Drive Wheel Baffle...
  • Page 16 & nuts. Covers. (Pic.2.2.10) (Pic.5.2.11) Step 12 ※ Put the Filter Net into the iCleaner-120, press down on the filter net until the Latch locks into the bracket.the filter until the Latch locks into the bracket (Pic.5.2.12) (Pic.5.2.12)...
  • Page 17 5.3 Water Retaining Board Replace the Water Retaining Board if they are broken(Pic 5.3.1) hole Step 1 ※ Remove the base plate from the iCleaner and remove the filter bag, then open the water retaining board to the vertical position and carefully slide the water retainining board to one end, remove the water retainining board carefully.
  • Page 18 Note: The Power Box MUST BE DISCONNECTED from the power supply prior to conducting any maintenance on the iCleaner-120. Contact your local distributor, or place of purchase for problems not covered in Trouble Shooting Guide. - 17 -...
  • Page 19 Indicator Indicator Solution Solution Failure Failure light light 1.Check whether the impeller is damaged; The iCleaner Green light Green light 2.Check whether the water pump motor is working; has stopped Water Return the robot to deeper water and restart flashing flashing 3.Put the robot in the water.

Table of Contents