PRODUCT SPECIFICATIONS
Maximum seating capacity:
Water capacity:
Inner/outer size:
Height:
Bubble air blower:
Filter pump fl ow rate:
Heater power:
Temperature range:
Temperature rise:
Number of Bubble Jets:
Spa tub recommended working air pressure:
Radio frequency radiation exposure Information:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance of 20 cm (7.9'') between the radiator
and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Cord-connected spa with pump, heater, blower, built-in hard water treatment and control panel.
Note: the spa equipment features a complete grounding system that is also in contact with the spa water. It
is possible that a person may build up static electricity that discharges when touching the water. Regardless,
any electric shock experienced should be investigated by a qualifi ed electrician prior to use of the spa.
Unplug the spa until the cause is determined and any corrective action completed.
Risk of fi re: This product draws a minimum of 13 AMPS. Most household circuits are 15 to
20 AMPS. If the circuit breaker trips, please check that no other appliances or other large
loads are on the same circuit as the spa. Never use an extension cord. Unfold the line
cord prior to use. Never place the plug on combustible materials.
Site preparation and requirements
• The spa can be installed indoor or outdoor. For household use only.
• The spa must be setup on a level, fl at and smooth surface that is capable of supporting the maximum
load of the fi lled spa with four adult occupants: weight 2500 lbs (1136 kg); six adults: 3500 lbs (1592 kg).
• Make sure the area is free of sharp objects under or around the spa.
• Provide adequate drainage system around the spa to deal with overfl ow water and splashes.
• Provide a properly located power outlet to connect the spa and allow easy access for periodic testing of
the cord mounted GFCI/RCD.
• Make sure there is enough clearance around the spa for full access to the spa equipment for
maintenance and/or service.
• The area shall facilitate draining purposes during long term spa storage.
NOTE: Before setting up and fi lling the spa with water, make sure the area where the spa will be installed
is within your WiFi router coverage range. The area shall be free from metallic walls/mesh and other
objects that may interfere with or reduce the WiFi signal.
Additional requirements for indoor installation
• Make sure the fl oor can support the full weight of the fi lled spa with the maximum number of occupants.
Check with a qualifi ed contractor or a structural engineer to verify this requirement.
• Make sure the fl oor is water resistant and non-slip surface. Do not install the spa on carpet or other
materials that will be damaged by moisture, condensation.
• Do not install the spa indoors on a second fl oor above fi nished living space due to the possibility of water
and humidity damage.
S AVE THESE INSTRUCTIONS
(352PO) SPA ENGLISH 7.5" X 10.3" PANTONE 295U 12/16/2021
4 adults
210 gal (795 L)
57/77 in (145/196 cm)
1.1 HP / 110-120 V / 60 Hz
460 gal/hr (1,741 L/hr)
1,300 Watts / 110-120 V / 60 Hz
50ºF – 104ºF (10ºC – 40ºC)
2-3ºF/hr (1-1.5ºC/hr)
140
WARNING
SET UP
English
6 adults
290 gal (1098 L)
65/85 in (165/216 cm)
28 in (71 cm)
1-2ºF/hr (0.5-1ºC/hr)
170
0.083 bar (1.2 psi)
352