Failure Indicator Display:
Indicates a malfunction of the indoor room temperature sensor.
Indicates a malfunction of the evaporator temperature sensor.
Indicates a malfunction of the outdoor condenser temperature sensor.
Indicates frosting protection (Turn off the unit and restart it to return to normal operation).
Note:
When one of the above malfunctions occurs, turn off the unit, and check for any obstructions.
Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord.
Contact the manufacturer or its service agents or a similar qualified person for service.
SPECIFICATIONS
Unit dimensions:
MODEL(Btu/h)
7000
9000
12000
18000
Minimum nominal cross-sectional area of conductors:
Nominal cross-sectional area
2
(mm
)
0.75
1.0
1.5
2.5
BODY DIMENSION(mm)
(W x H x D)
450x346x585
600x380x560
660x428x680
660x428x780
Rated current of
appliance (A)
>3 and ≤6
>6 and ≤10
>10 and ≤16
>16 and ≤25
17
WIRING SIZE
2
(mm
)
≥ 3*1.5
≥ 3*1.5
≥ 3*1.5
≥ 3*2.5