Turbo Air TA1500 Manual page 13

100l/min oil-less
Table of Contents

Advertisement

IMPORTANT
NOTE
This compressor has a maximum pressure of 8 bar.
Always regulate the air pressure to match your air
tool. Different air tools require different operating
pressures. Always check with the tool manufacturer
if unsure.
100L/MIN OIL - LESS COMPRESSOR
compressor
compressor
compressor
Call Euroquip for the approved Turbo Air service agent in your area
Euroquip NZ: 0800 387 678
Euroquip Australia: 1800 040 947
TROUBLE SHOOTING
compressor
will not start
Check that you have plugged the power lead into a standard 240V 10Amp
power point and turned the switch ON.
Check that you have turned the the pressure decreases to 85PSI.
ON/OFF switch ON.
The air tank may be full. Use your air tool and the compressor should start
when the pressure decreases to 85PSI.
compressor
will not startdoes not build up pressure
Check that the tank drain tap is sealed
Check that the air fi tting is not leaking. If leaking replace.
compressor
will not start smells like burnt oil
Using beyond the 50% duty cycle, allow to cool for 30 minutes before
reusing this compressor.
compressor
13.

Advertisement

Table of Contents
loading

Table of Contents