Summary of Contents for Turbo Air TA1500

  • Page 1 100L/MIN OIL-LESS COMPRESSOR Silent portable compressor ideal for general inflating tasks. MODEL NO. TA1500 Read this material before using this product. Failure to do so can result in injury. SAVE THIS MANUAL For spare parts or product information please email customerservice@euroquip.co.nz...
  • Page 2: Table Of Contents

    100L/MIN OIL - LESS COMPRESSOR CONTENTS INTRODUCTION............3 COMPONENTS AND CONTROLS........8 OPERATING INSTRUCTIONS........9 STARTING AND STOPPING YOUR COMPRESSOR..10 USING THE INFLATOR..........11 TOOL CONFIGURATION..........11 TA1500 PARTS LIST............14 TA1500 PUMP PARTS LIST..........15 WARRANTY ..............16...
  • Page 3: Introduction

    Euroquip NZ: 0800 387 678 Euroquip Australia: 1800 040 947 COMPRESSOR If you have a problem, call customer service do not return this SPECIFICATIONS: Compressor to the place of purchase. Model: TA1500 VOLTAGE: 230V FREQUENCY: 50Hz Power: 1.5HP Tank Size:...
  • Page 4 100L/MIN OIL - LESS COMPRESSOR LUBRICATION OF COMPRESSOR WORK AREA This infl ator is OIL FREE. Therefore there is NO oil used for Work areas and benches should be kept tidy. Cluttered lubrication. benches and work areas can cause accidents. Floors should be kept clean and free from rubbish.
  • Page 5 100L/MIN OIL - LESS COMPRESSOR DO NOT ABUSE THE POWER CORD REMOVE ADJUSTING KEYS AND WRENCHES Never yank or pull on the power cord to disconnect it from the mains supply socket. Never carry or pull your compressor Form the habit of always checking to see that any adjusting by its power cord.
  • Page 6 100L/MIN OIL - LESS COMPRESSOR CHECK DAMAGED PARTS PERSONAL SAFETY Clothing Before using the compressor it should be carefully checked to determine that it will operate properly and perform its Do not wear loose clothing, jewellery or anything that could intended function.
  • Page 7 100L/MIN OIL - LESS COMPRESSOR IMPORTANT ELECTRICAL DATA This compressor is fi tted with a sealed electrical connection plug that is compatible with the mains power supply for Australia / New Zealand and meets the requirements of Australian Standards. This compressor must be connected to a supply voltage that is equal to that stated on the rating label.
  • Page 8: Components And Controls

    100L/MIN OIL - LESS COMPRESSOR PIC. 1 COMPONENTS AND CONTROLS Pic. 1 1. Pressure switch 2. On / Off button - red colour 3. Handle 4. Quick Connect Outlet 5. Pump 6. Tank 7. Rubber feet 8. Tank drain tap 9.
  • Page 9: Operating Instructions

    100L/MIN OIL - LESS COMPRESSOR OPERATING INSTRUCTIONS PIC. 2 Unpacking Carefully unpack your compressor. Dispose of all packing material in an environmentally responsible manner. Assembly compressor r i u i n i a i t o i t Check that you have all required components required for assembly and initial use.
  • Page 10: Starting And Stopping Your Compressor

    100L/MIN OIL - LESS COMPRESSOR STARTING AND STOPPING YOUR COMPRESSOR NOTE: Always ensure that you plug your compressor into a PIC. 4 standard 240V AC power point. Never use an extension cord as this can lead to a voltage drop which may cause power loss and over heating.
  • Page 11: Using The Inflator

    100L/MIN OIL - LESS COMPRESSOR USING THE COMPRESSOR TOOL CONFIGURATION The confi guration of tools and accessories can be varied to Before starting run through this simple list; suit your particular requirements. A basic recommended set Ensure the compressor is fully assembled up is shown in Pic.
  • Page 12 100L/MIN OIL - LESS COMPRESSOR ADJUSTING THE PRESSURE PIC. 8 To adjust the outlet air pressure, use the red coloured regulator knob and check the pressure on the outlet pressure gauge, Pic. 7. If the pressure needs to be lower, Pull to check turn anti clockwise.
  • Page 13 100L/MIN OIL - LESS COMPRESSOR compressor compressor compressor compressor Call Euroquip for the approved Turbo Air service agent in your area Euroquip NZ: 0800 387 678 Euroquip Australia: 1800 040 947 TROUBLE SHOOTING compressor will not start Check that you have plugged the power lead into a standard 240V 10Amp power point and turned the switch ON.
  • Page 14: Ta1500 Parts List

    100L/MIN OIL - LESS COMPRESSOR TA1500 PARTS LIST Tank (Coated) Pump Head One Way Valve Air Filter 1/4 Realease Tube Capacitance Cover Discharge Tube Pump Rubber Screw Outlet Capacitance Rubber Connect Tube Pressure Switch 4 -Way Regulator Safety Valve Gauge...
  • Page 15: Ta1500 Pump Parts List

    100L/MIN OIL - LESS COMPRESSOR TA1500 PUMP PARTS LIST Fan Cover Cylinder Head Fan A Connect Tube Crank Eblow Connector Bearing 6006-2Rs Fan B Conrod Crankcase B Piston Ring Bearing 6203-2rs Piston Cover Stator Cylinder Rotor Valve Seal Crankcase A...
  • Page 16: Warranty

    Euroquip customer service on 0800 387 678. a warranty claim is made at the sole jurisdiction of Euroquip. Registered warranty period for the TA1500: Commercial Use: 18 Months No costs incurred will be considered under warranty Domestic Use: 18 Months...
  • Page 17 100L/MIN OIL - LESS COMPRESSOR...
  • Page 18 100L/MIN OIL - LESS COMPRESSOR...
  • Page 19 100L/MIN OIL - LESS COMPRESSOR...
  • Page 20 Congratulations on your new TURBO AIR product. We are proud to have you as our customer and will strive to provide you with the best service and reliability in the industry. This product is backed by our extensive warranty and service network. To locate your nearest distributor or service agency...

Table of Contents