2. Technical data

Name: Pneumatic burner cleaner - accessory
Prescribed burner: ATMOS A85 with AC07X regulation with additional module AC07X-C
Power supply: 230 V / 50 Hz
Maximum power when using supplied compressor: 1500 W
Maximum power when using other equipment: according to equipment type
Control of functions: electronic regulation of burner AC07X with additional module AC07X-C,
controlling both burner pneumatic cleaning and burner and boiler operations. Function using all
reserve outlets R, R2, R5 and R6, which thus cannot be used for other purposes.
Profile of the device: A85 pneu C
Other necessary information is included in the burner manual and manual for your specific boiler.
Pneumatic cleaner operating pressure: 4 - 5 bar (400 - 500 kPa)

3. Assembly instructions

WARNING – pneumatic cleaner assembly may only be undertaken by a qualified
person trained by the manufacturer in accordance with rules and regulations in force.
Before running, you must familiarise yourself completely with the operation manual. You
must also observe all general safety regulations for working with heating equipment and
pressure vessels which are given by laws in force.

Assembly of the pneumatic cleaner in pictures

Connect the connecting cable to the valve head
8-EN
Operation and Maintenance Manual - EN
(Burnner profile has to be set at: A85 pneu C)
www.atmos.cz
Take complete screw fitting with solenoid control
and connecting cable and screw it to the burner