Operation and Maintenance Manual - EN CONTENTS 1. Introduction CP85KS set for A85 burner with compressor 2. Technical data 3. Assembly instructions Assembly of the pneumatic cleaner in pictures Connecting the compressed air system Installing the burner and connecting it to the boiler 4.
Operation and Maintenance Manual - EN 1. Introduction The pneumatic burner cleaner is an accessory suitable for optimal cleaning of the ATMOS A85 combustion chambers when burning poorer quality wooden pellets which form cakes (ash clumps), i.e. wooden pellets with greater amounts of bark and dirt.
Page 5
- pressure hose 2 m - cable with 3-pin connector (female) Compressor accessories for compressor use as a source of compressed air. This accessory use, if we want the compressor to run independently for example to blow out inside of the burner. www.atmos.cz EN-5...
Operation and Maintenance Manual - EN CP85KS set for A85 burner with compressor for pellet boilers with exhaust fan: D80P, P80 Set contents: - connecting air hose of length 1 m (diameter 28 mm) code: S0767 - complete screw fitting (3/4”) with solenoid control...
Page 7
(400 - 500 kPa) kompresor 24 l elektroventil 4 – 5 bar elektroventil hořáku hořáku vzdušník přídavný 12 - 24 l elektroventil Installation using a second solenoid valve and Standard installation using the supplied com- an additional receiver pressor www.atmos.cz EN-7...
Operation and Maintenance Manual - EN 2. Technical data Name: Pneumatic burner cleaner - accessory Prescribed burner: ATMOS A85 with AC07X regulation with additional module AC07X-C (Burnner profile has to be set at: A85 pneu C) Power supply: 230 V / 50 Hz...
Installing the burner and connecting it to the boiler Affix the pellet burner to the appropriate boiler Connect the connecting cable with a 6-pin co- and fully tighten nnector on both ends between the burner and boiler www.atmos.cz EN-9...
Page 10
8 A inductive load… Code: S0090 (Note – cannot normally be bought in shops) WARNING - ATMOS A85 pellet burner has two mains lead, therefore disconnect (boiler, compressor) before uncover the burner hood. WARNING – the compressor must never be powered directly from the boiler.
WARNING - Wiring may only be undertaken by a qualified person in accordance with all rules and regulations of your country with careful attention paid to ensuring the safe earthing of the boiler and burner. Wiring system for boiler running on pellets only without exhaust fan - D80P, P80 www.atmos.cz EN-11...
(explosive type) because of possible dusting into the boiler room. If required, install draught limiter into the cleaning hole at the foot of the chimney. www.atmos.cz 12-EN...
INFO - Pneumatic burner cleaning is completely safe, since it is performed once the fuel has fully burnt. Nevertheless, do your utmost to ensure the boiler remains relatively clean. Boiler exhaust fan The boiler exhaust fan ensures suction pressure un the combustion chamber when operating a pellet burner. www.atmos.cz EN-13...
When setting where parameter S1 is set to a value of 4, which means that at the start both ignition coils are run, you can connect an appliance of maximum current 0.29 A (approx. 67 VA) to R, R2, R5 and R6 reserve terminals together. www.atmos.cz 14-EN...
Page 15
... (10 s) - standardly do not change INFO - pellet burner A85 pre-cleans the burner‘s combustion chamber three times. The cleaning is characterized by parameters S58, S59, S60. Do not change these parameters by any means. www.atmos.cz EN-15...
Page 16
WARNING - to regulate and set the optimal amount of compressed air for pneumatic cleaning of the burner, never use the solenoid opening time which is directly set on the burner (never parameter S45). www.atmos.cz 16-EN...
Cleaning of the channels for compressed air inflow to the combustion chamber is undertaken in dependence on the quality of pellets from once a month to once every 4 months. Slight clogging after 4 months of use Example of cleaning the front part of the compre- ssed air inflow channel www.atmos.cz EN-17...
Page 18
As needed, but at least once a season blow out (vacuum up) space inside the burner. WARNING - electronic unit AC07X with additional module AC07X-C never cleaned mechanically. Example of cleaning (blow out) space inside Example of cleaning (blow out) pressure fan the burner. (without power!) impeller of the burner once a season www.atmos.cz 18-EN...
Page 19
WARNING - The air receiver (compressed air container) is a pressuried container and must be regularly checked with regular services carried out on it in accordance with the law in force in your country. Checking oil levels in compressor Cleaning compressor filter www.atmos.cz EN-19...
Warranty and post-warranty repairs are performed by: - the company representing ATMOS in your country for your region - the assembly company which installed the product - Jaroslav Cankař a syn ATMOS, Velenského 487, 294 21 Bělá...