6 pole DIP switch
Various wind and rain parameters and operating modes can be set by
means of the integrated 6 pole DIP switch.
Once the sensor is installed and operational, the DIP switches
should be set to the settings as shown below:
Switch 1
OFF
Switch 2
OFF
Switch 3
Switch 4
Switch 5
OFF
Switch 6
OFF
IMPORTANT: Factory setting = Test setting.
Note: In the test setting, activation and drop out delay is deactivated!
If the red light-emitting diode in the sensor is lit, the sensor has been
activated by wind and/or rain and the modular skylight closes.
Other settings are possible. It is, however, not advisable to use the
10 m/s, 12 m/s or 14 m/s wind speed settings as there is the risk of dam-
age to fittings before the modular skylight can close fully. These settings
are used at your own discretion.
DIP switch settings for wind speed
Test
Switch 1
OFF
Switch 2
OFF
Switch 3
OFF
DIP switch setting for wind activation delay
Switch 4
DIP switch setting for wind/rain drop out delay
Switch 5
DIP switch setting for monitoring (not supported by the system)
Switch 6
Connection to power supply unit KUX 110 and interface KLF 200
Terminal 1: Supply voltage AC/DC
Terminal 2: Supply voltage AC/DC
Terminal 3: Relay (C)
Terminal 4: Relay (N/C contact)
Terminal 5: Relay (N/O contact)
Note: Please refer to the instructions for these products that are for
indoor installation only.
ON
ON
Approx
Approx
3 m/s
4 m/s
ON
OFF
OFF
ON
OFF
OFF
2 seconds
OFF
10 minutes
OFF
OFF
Approx
Approx
Approx
6 m/s
8 m/s
10 m/s
ON
OFF
ON
OFF
OFF
ON
5 seconds
ON
20 minutes
ON
ON
Approx
Approx
12 m/s
14 m/s
ON
OFF
OFF
ON
ON
ON
VELUX
ON
ON
ON