Balboa BP600 Manual page 13

Hide thumbs Also See for BP600:
Table of Contents

Advertisement

TP400, TP600 Messages (cont.)
FLOW-RELATED CHECKS
Check for low water level, suction flow restrictions, closed
valves, trapped air, too many closed jets and pump prime.
On some systems even when spa is shut down, some equipment
may occasionally turn on to continue monitoring temperature or
if freeze protection is needed.
102˚F SNSR BAL-- ANCE
Sensor Balance is Poor – M015
The temperature sensors MAY be out of sync by 2°F or 3°F.
SNSR SYNC -- -- -- -- CALL FOR SRVC -- -- -- --
Sensor Balance is Poor* – M026
The temperature sensors ARE out of sync. The Sensor Balance is
Poor fault has been established for at least 1 hour.
SNSR A -- -- -- -- CALL FOR SRVC -- -- -- --
SNSR B -- -- -- -- CALL FOR SRVC -- -- -- --
Sensor Failure – Sensor A: M031, Sensor B: M032
A temperature sensor or sensor circuit has failed.
NO COMM
No Communications
The control panel is not receiving communication from the
System.
BETA VER-- SION -- -- -- --
Pre-Production Software
The Control System is operating with test software.
102 T
°F or °C is replaced by °T
The Control System is in Test Mode.
MEM FAIL -- -- -- --
Memory Failure - Checksum Error* – M022
At Power-Up, the system has failed the Program Checksum Test.
This indicates a problem with the firmware (operation program)
and requires a service call.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
60
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
MEM RSET -- -- -- --
Memory Warning - Persistent Memory Reset* – M021
Appears after any system setup change. Contact your dealer
or service organization if this message appears on more than
one power-up, or if it appears after the system has been running
normally for a period of time.
CLOK FAIL -- -- -- --
Memory Failure - Clock Error* – M020
Not Applicable on the BP1500.
CNFG FAIL -- -- -- --
Configuration Error - Spa will not Start Up
GFCI FAIL -- -- -- --
GFCI Failure - System Could Not Test/Trip the GFCI – M036
NORTH AMERICA ONLY. May indicate an unsafe installation.
STUK PUMP -- -- -- --
A Pump Appears to be Stuck ON – M034
Water may be overheated. POWER DOWN THE SPA. DO NOT
ENTER THE WATER.
HOT FALT -- -- -- -- CALL FOR SRVC -- -- -- --
A Pump Appears to have been Stuck ON when spa was
last powered – M035
POWER DOWN THE SPA. DO NOT ENTER THE WATER.
2013-06-22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bp2100g1Tp900Tp800Tp600Tp400

Table of Contents